Laserfiche WebLink
Well Increasing Trends Decreasing Trends <br /> Number <br /> AMW-1 Barium, Bicarbonate, Specific Nitrate-N,pH, Sulfate,DCDFM, 1,3-DCB <br /> Conductance, 1,1-DCA, <br /> Chlorobenzene,cis-1,2-DCE <br /> AMW-3 None Apparent None Apparent <br /> AMW-4 Nitrate-N,pH Bicarbonate,Calcium,Chloride, Magnesium, <br /> Potassium, Specific Conductance,Strontium,TDS, <br /> l,l-DCA, 1,2-DCP, 1,4-DCB,cis-1,2-DCE, <br /> DCDFM,PCE,TCE,trans-1,2-DCE, <br /> Vinyl Chloride <br /> AMW-5R Bicarbonate,Chloride,Nitrate-N, Magnesium,PCE <br /> pH, Specific Conductance, <br /> Sulfate,TDS <br /> AMW-10 Sulfate Barium, Bicarbonate,Calcium,Chloride, <br /> Magnesium,Nitrate-N,Potassium, Sodium, <br /> Specific Conductance, Strontium,TDS, 1,1-DCA, <br /> DCDFM, PCE,TCE <br /> AMW-11 pH Barium,Carbonate,Chloride,Magnesium, <br /> Potassium, Specific Conductance,TDS, 1,1-DCA, <br /> 1,2-DCP,cis-1,2-DCE, DCDFM,PCE,TCE <br /> trans-l,2-DCE <br /> AMW-18 Bicarbonate Carbonate,Chloride,Nitrate-N, Potassium, <br /> Sodium, Sulfate,TDS <br /> AMW-19 Barium Hexavalent Chromium,Nitrate-N, Sodium,Sulfate <br /> AMW-19BR Chloride,pH Hexavalent Chromium,Nitrate-N,Potassium, <br /> Sodium, Sulfate,cis-1,2-DCE <br /> Notes: l,4-DCB—1,4-dichlobenzene 1,2-DCP—1,2-dichloropropane trans-1,2-DCE—trans-1,2-Dichloroethene <br /> As shown in the table above, significant increasing trends were calculated for three VOC <br /> constituents in CAP well AMW-1, while decreasing VOC trends were noted for several <br /> VOCs in CAP wells AMW-1, AMW-4, AMW-5 , AMW-10, AMW-11, and AMW- <br /> 1913R. The increasing trend exhibited for cis-1,2-DCE at wells AMW-1, suggests <br /> reductive dechlorination is occurring in the vicinity of this well. <br /> 3.1.6 Domestic Well Monitoring <br /> Two domestic wells (7898-A and 8106-A) were sampled on February 24, 2012. Table <br /> 3-3 summarizes the current analytical results for the domestic well samples collected. In <br /> the samples collected from wells 7898-A and 8106-A, PCE and TCE were measured <br /> above the PQL, TCFM was also measured above the PQL in the sample collected from <br /> well 8106-A. Estimate trace concentrations of three VOCs were measured in the sample <br /> collected from well 7898-A, and two VOCs were measured at trace concentrations in the <br /> sample collected from well 8106-A. <br /> 3.1.7 Surface Water Monitoring <br /> During the first quarter 2012 monitoring period, both surface-water monitoring stations <br /> ASW-1 and ASW-2 were reported dry by Del-Tech on February 22, 2012. <br /> C:\2012-0025\FA_IQI2.doc 11 Geo-Logic Associates <br />