Laserfiche WebLink
the data. Trend analyses,are presented in Appendix D and are summarized below. Wells <br /> and analytes not discussed below either do not show significant trends (rising or falling) <br /> or have too few data points to establish meaningful trends. <br /> Well Increasing Trends Decreasing Trends <br /> Number <br /> AMW-1 Arsenic,Barium, 1,1-DCA, Nitrate,pH,Sodium, Sulfate,DCDFM <br /> Chlorobenzene,cis-1,2-DCE <br /> AMW-3 - - <br /> AMW-4 pH Chloride,Potassium,TDS, 1,1-DCA, 1,4-DCB, <br /> Benzene,cis-1,2-DCE,DCDFM,PCE,TCE, <br /> trans-1,2-DCE,Vinyl Chloride <br /> AMW-5R - Chloride <br /> AMW-10 Sulfate Barium,Bicarbonate,Calcium,Chloride, <br /> Hexavalent Chromium,Magnesium,Nitrate, <br /> Potassium,Sodium, Strontium,TDS, 1,1-DCA, <br /> DCDFM,PCE,TCE <br /> AMW-11 pH Chloride,Hexavalent Chromium,Magnesium, <br /> Nitrate,Potassium,TDS, 1,1-DCA,cis-1,2-DCE, <br /> DCDFM, PCE,TCE,trans-1,2-DCE <br /> AMW-18 Bicarbonate- Carbonate,Chloride,Hexavalent Chromium, <br /> Potassium, Sodium,Sulfate,TDS <br /> AMW-19 Barium,Chloride Hexavalent Chromium,Nitrate,Sulfate <br /> AMW-19BR Barium,Calcium,Chloride,pH Hexavalent Chromium,Nitrate, Sulfate, l,l-DCA, <br /> cis-1,2-DCE <br /> Notes: 1,4-DCB—1,4-Dichlorobenzene trans-12-DCE—trans-1,2-Dichloroethene <br /> 1,2-DCP—1,2-Dichloropropane PCE—Tetrachloroethene <br /> TDS—Total Dissolved Solids TCE—Trichloroethene <br /> As shown in the table above, significant increasing trends were calculated for three VOC <br /> constituents in CAP well AMW-1, while decreasing VOC trends were noted for several <br /> VOCs in CAP wells AMW-1, AMW-4, AMW-10, AMW-11, and AMW-19BR. The <br /> increasing trend exhibited for cis-1,2-DCE at well AMW-1, and generally decreasing <br /> (organic and inorganic)trends noted in all of the CAP wells, suggests that corrective <br /> action measures have been successful in reducing facility related groundwater impacts <br /> downgradient of the Austin Unit. <br /> Domestic Well Monitoring <br /> Two domestic wells(7898-A and 8106-A)were sampled on August 2, 2013. Table 3-3 <br /> summarizes the current analytical results for the domestic well samples collected. PCE <br /> was measured above the PQL in the samples from both domestic wells and DCDFM and <br /> TCE were measured above the PQL in the sample collected from well 8106-A. <br /> Estimated-trace concentrations of two VOCs were also measured in the samples collected <br /> from wells 7898-A and 8106-A. <br /> Surface Water Monitoring <br /> Site run-on and run-off control facilities are designed to effectively channel surface water <br /> to site stormwater/sedimentation ponds. According to the Operations Manager, there <br /> were no discharges to surface water during the reporting quarter. Samples were collected <br /> C:\2013-0021\FA_3Q13.doc 11 Geo-Logic Associates <br />