My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2013_4
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2013_4
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:43 PM
Creation date
7/3/2020 10:57:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2013_4
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2013_4.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
287
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-INSTALL SILT FENCE 4 NOTES: <br /> CHEVRON j D4 7) THE LENGTH OF EACH REACH OF SILT FENCE IN NO CASE SHALL EXCEED 500' USE GRAVEL BAG CROSS FABRIC SECTION B <br /> GRAVEL BAGS ' TAMPED BARRIERS SPACED PEP. TABLE 1 AT RIGHT (SEE NOTES 6,7 & 12)� ` HOG RING <br /> PER PLAN— BACKFILL 4 TIE WIRE <br /> 7.5' I T 2) THE LAST B'-0" OF EACH REACH OF FENCE SHALL BE TURNED UP SLOPE PEP, DETAIL DA STAKE 8-, <br /> BENCH 7_5� � <br /> • of ��-- 3) STAKE DIMENSIONS ARE NOMINAL. / <br /> 4) DIMENSIONS MAY VARY TO FIT FIELD CONDITION. STAKE A FABRIC `—STAKE <br /> y <br /> NI 6-! 5) STAKES SHALL BE SPACED AT 8'-0"MAXIMUM AND SHALL BE POSITIONED ON DOWNSTREAM SIDE OF FENCE. 1 <br /> FABRIC SECTION A- <br /> 6) JOINING SECTION STAKES TO OVERLAP AND FENCE FABRIC TO FOLD AROUND EACH STAKE ONE FULL TURN. (SEE NOTES 6, 7 & 12) <br /> i 30 3 <br /> SECTION A-A SECURE FABRIC TO STAKE WITH 4 HOG RING TIES. <br /> JOINING SECTION DETAIL (TOP VIEW) HOG PING TIE DETAIL <br /> 4 _-- 7) JOINING SECTION STAKES SHALL BE DRIVEN TIGHTLY TOGETHER TO PREVENT POTENTIAL FLOW-THROUGH OF <br /> PA <br /> UNPAVED VED SEDIMENT AT JOINT. THE TOPS OF THE STAKES SHALL BE SECURED TO EACH OTHER WITH WIRE TIES TO <br /> GRADIENT SURFACE SURFACE PREVENT SEPARATION. <br /> -�, 7%-3% 200 250 8) FOR END STAKES, FENCE FABRIC SHALL BE FOLDED AROUND TWO STAKES, ONE FULL TURN AND SECURED <br /> 45• 39—s9 150 200 TABLE 7 <br /> WITH 4 HOG RING TIES. <br /> --i 59-79 loo 150 CROSS BARRIER <br /> �- 9) A MINIMUM OF 4 HOG RING TIES PER STAKE SHALL BE UTILIZED. DIMENSIONS SHOWN ARE TYPICAL. SLOPE OF BENCH/ROA T Z" x 2" WOOD STAKE <br /> PLAN 7� 9,-9% 50 100 �_ SPACING (FEET) (SEE NOTE 3) <br /> 9%+ 25 50 1 10) CROSS BARRIERS SHALL BE SPACED PER TABLE 1 AT RIGHT _09" 1 __100 FABRIC <br /> GRAVEL BAG CHEVRON DETAIL 7.07< s s 1.5% _75 (SEE NOTE B) <br /> i1) MAINTENANCE OPENINGS SHALL BE CONSTRUCTED IN A MANNER TO ENSURE THAT SEDIMENT REMAINS �-- <br /> BEHIND THE SILT FENCE. 7.5%< 5 S 2.09, � 50 I A <br /> NTS D4 2.0%< S 52, <br /> 50 <br /> 12) JOINING SECTIONS SHALL NOT BE PLACED AT SUMP LOCATIONS. I S5%< 5 S 3.0% 40 <br /> BENCH 13) GRAVEL BAG ROWS AND LAYERS SHALL BE OFFSET TO ELIMINATE GAPS F- END STAKE SECTION DETAIL <br /> 3.0%< 5 S 5.0% 30 (TOP VIEW) <br /> OPTIONAL 14) SILT FENCE FABRIC SHALL BE BURIED IN A TRENCH 6-INCHES WITH 6-INCH RETURN, AND SHALL BE r 5.0%< S 25 <br /> / BACKFILLED PER SECTION B-B, TO PREVENT SILT FROM UNDERMINING/BYPASSING FENCE FABRIC. <br /> INSTALL FIBER <br /> ROLLS PER 15) IN FLATTER SLOPE AREAS ADDITIONAL GRAVEL BAGS MAY BE REQUIRED TO MAINTAIN 72"' MIN SILT STORAGE <br /> — <br /> D4 i BEHIND CROSS BARRIER. <br /> x <br /> y � I m I <br /> WI <br /> W � <br /> a HYDROSEED- a pl BENCH oI <br /> BENCH <br /> U) �` i Z BENCH tjI Ll <br /> LLPER PLAN I <br /> BENCH- x� <br /> n l (�' TOE OF SLOPE <br /> ^' TOE OF SLOPE m <br /> SILT FENCE ADDITIONAL <br /> (SEE NOTE 75 <br /> SLOPE RATIO H I GRAVELBAGS \`4{� SILT FENCE-' <br /> 2:7 <br /> 7.5- <br /> 2.5:7 6.0' <br /> 31 5.0' SILT FENCE INSTALLATION DETAILS (STEEL STAKES) <br /> FIBER ROLL SPACING 2 GRAVEL BAGS <br /> NTS D4 (2-LAYERS HIGH) <br /> STAKE STAKE <br /> 2" x 2" WOOD STAKE SETBACK VARIES <br /> NpTES: (SEE NOTES 3 & 5) �i (SEE NOTE 4) <br /> 1) FIBER ROLL INSTALLATION A7 BENCH SHALL BE A MINIMUM <br /> OF 12"ABOVE BENCH FLOWLINE, UNLESS SILT FENCE IS 3/4"x 3/4"x 24" MIN \� <br /> SPECIFIED AT THAT LOCATION. LENGTH WOOD STAKES CROSS <br /> AT MAX 4' SPACING / BARRIER', SILT FENCE- <br /> -END STAKE SILT FENCE- END STAKE <br /> /-8" TO 10"0 1 GRAVEL BAGS FABRIC '� - T <br /> 2) A 3" DEEP TRENCH, THE WIDTH OF THE ROLL, DUG PER SLOPE ROLL { (SEE NOTE 2) q/ +SEE <br /> PLAN LOCATION SHALL "NEST" THE STRAW ROLL SO AS NOT <br /> 70 ALLOW RUNOFF TO FLOW UNDER OR AROUND ROLL. (PLACED ON T0� PE END STAKE NOTE 1 1 <br /> o j <br /> CONTOUR) 7 o <br /> 3) FIBER ROLLS SHALL BE PLACED ON SLOPES AT H-FEET :Z: %I OPTIONAL MAINTENANCE OPENING DETAIL <br /> VERTICAL INTERVALS STARTING FROM THE TOE OF RESPECTIVE 3 I SLOPE <br /> SLOPE. DECK ROLLS SHALL BE PLACED AT 10-FEET VERTICAL Z)0' CROSS__ <br /> INTERVALS AS SHOWN ON THE PLAN. — SILT FENCE (SEE NOTE 15) e <br /> �ni � BARRIER �' <br /> 4 INSTALL FIBER ROLLS ALONG A LEVEL CONTOUR. GRAVEL BAGS <br /> 14 s <br /> �_� �_ <br /> W TAMPED % LI <br /> 5) INSTALL FIBER ROLLS UP GRADIENT AND NEAR TRANSITION v mi =_ o <br /> � _ li � _ z BACKFILL <br /> OF SLOPES. I 1I <br /> x <br /> 6) INSTALL NUMEROUS ROLLS IN A ROW BY OVERLAPPING, —I ;_;_, 1 —� I—� =� —� �_� I Z, g �V '1�0 <br /> NOT ABUTTING. - —_� —� �_� �_� —_� (_� �— gl N a -SEE TABLE 1 TOE OF <br /> FOR SPACING SLOPE <br /> 7) TURN ENDS OF ROLLS UP SLOPE TO PREVENT RUNOFF - <br /> FROM GOING AROUND THE ROLL. —III —I —III TOE OF SLOPE CROSS BARRIER GRAVEL BAG DETAIL <br /> SECTION C- SECTION B-8 <br /> 8) SEDIMENT IS TO BE REMOVED WHEN ACCUMULATION li <br /> END DETAIL C <br /> REACHES ONE HALF THE DISTANCE BETWEEN THE TOP OF THE 4 <br /> ROLL AND ADJACENT GROUND SURFACE. FIBER ROLLS 3 SILT FENCE INSTALL NTS D4 <br /> NTS D4 <br /> C ® r SERVICES <br /> PREPARED BY: pppvEss,� FORWARD LANDFILL <br /> ® REPUBLIC SERVICES clvu&t�+vl>onme^tom /g�� "CU 9y STAGE 1B PARTIAL FINAL CLOSURE PROJECT <br /> FORWARD LANDFILL$ INC T Engineering EROSION CONTROL DETAIL SHEET D4 <br /> � Ic mo,e ea � DESIGNED BY RMG SCALE AS SHOWN <br /> 9999 S. AUSTIN ROAD 800-C SOUTH ROCHESTER AVENUE \�\ DRAWN BY : JPJ DATE 6-2011 FILE NO.: <br /> MANTES., CALIFORNIA 95336 ONTARIO, CALIFORNIA 91761 \�"r��1'v1 � P CHECKED BY : DATE : 6-2011 <br /> (800) 204-4242 V FORWARD, INC. (2011) PREPARED UNDER TME SUPERVISION OF DATE APPROVED BY : DATE : 6-2011 FIGURE 10 <br /> N0, REVISION DESCRIPTION BY: _..n+c,crs�x..reo w.scvoM,r+m�sa,e nosu�cw�a�ncu«csvc.o nn-cc xwi sxcR o. <br />
The URL can be used to link to this page
Your browser does not support the video tag.