Laserfiche WebLink
Aft Product Specification - Structural Geogrid UX1400HS <br /> Tensar Earth Technologies,Inc.reserves thelright to change its product specifications at any time. It is the responsibility of the specifier and purchaser to <br /> ensure that product specifications used for design and procurement purposes are current and consistent with the products used in each Instance. Please <br /> contact Tensar Earth Technologies,Inc.at 860236.7272 for assistance <br /> Y The structural geogrid shall be an integrally formed grid structure manufactured of a stress resistant high density polyethylene material <br /> with molecular weight and molecular characteristics which impart:(a)high resistance to loss of load capacity or structural integrity when <br /> the geogrid is subjected to mechanical stress in installation;(b)high resistance to deformation when the geogrid is subjected to applied <br /> force in use;and(c)high resistance to 16ss of load capacity or structural integrity when the geogrid is subjected to long-term <br /> environmental stress. <br /> The structural geogrid shall accept applied force in use by positive mechanical interlock(i.e.by direct mechanical keying)with:(a) <br /> compacted soil or construction fill mater(als;(b)contiguous sections of itself when overlapped and embedded in compacted soil or <br /> construction fill materials;and(c)rigid mechanical connectors such as bodkins,pins or hooks.The structural geogrid shall possess <br /> sufficient cross sectional profile to prese M a substantial abutment interface to compacted soil or particulate constriction fill materials and <br /> to resist movement relative to such matrials when subject to applied force. The structural geogrid shall possess sufficient trtie initial <br /> modulus to cause applied force to be transferred to the geogrid at low strain levels without material deformation of the reinforced structure. <br /> The structural geogrid shall possess complete continuity of all properties throughout its structure and shall be suitable for reinforcement of <br /> compacted soil or particulate constructio fill materials to improve their long term stability in structural load bearing applications such as <br /> earth retention systems. The structural geogrid shall otherwise have the following characteristics: <br /> Product Type: Integrally Formed Structural Geogrid <br /> Load Transfer Mechanism: PositiVe Mechanical Interlock <br /> Product Properties <br /> Load Capacity Units MD Valued <br /> - True Initial Modulus in Use kN/m(lb/ft) 950(65,110) <br /> • Tensile Strength 1§5%Strain kN/m(lb/ft) 31 (2,130) <br /> - Ultimate Tensile Strength2 kN/m(ib/ft) 70(4,800) <br /> • Long-Term Allowable Load in Sands,Silts&Clay' kN/m(lb/ft) 30.2(2,070) <br /> • Long-Term Allowable Load In Well Graded Sandi kN/m(lb/ft) 29.3(2,010) <br /> IF • Long-Term Allowable Load in Agg 'gate' kN/m(lb/ft) 28.8(1,970) <br /> Integrity of Product Structure <br /> • Junction Strength i kN/m(lb/ft) 66(4,520) <br /> • Flexural Stiffness5 X1000 mg-cm 730 <br /> Durability <br /> • Resistance to Installation Damages %SC/%SW/%GP 95/92190 <br /> • Resistance to Long Term Degradation % 100 <br /> Dimensions and Delivery <br /> The structural geogrid shall be delivered to the jobsite in roll form with each roll individually identified and nominally measuring 1.33 <br /> meters(4.36 feet)in width and 76.2 meters(250.0 feet)in length. A typical truckload quantity is 324 rolls. 4n special request,the <br /> structural geogrid may also be custom cut to speck lengths or widths to suit site specific engineering designs. <br /> Notes <br /> 1.Unless indicated otherwise,values shown are minimum average roll values determined in accordance with ASTM D-4759. Brief descriptions of test <br /> procedures are given in the following notes. Complete descriptions of test procedures are available on request from Tensar Earth Technologies, <br /> inc. <br /> 2.True resistance to elongation when in"lly subjected to a load measured via ASTM D6637 without deforming test materials under load before <br /> measuring such resistance or emploft"secant"or"offset tangent methods of measurement so as to overstate tensile properties. <br /> 3.True strength available for resisting foaoe in long-term load bearing applications is determined by reducing ultimate tensile strength by state-of- <br /> practice factors for installation damage degradation in use,product integrity limitations and long-term product deformation per GRl-GG4. <br /> 4.Load transfer capability measured via GRI-GG2-87. <br /> 5.Resistance to bending force messureq via ASTM 0.5732-95,using specimen dimensions of 864 millimeters in length by 1 aperture in width. <br /> 6.Resistance to loss of load capacity or T tructural integrity when subjected to mechanical installation stress in clayey sand(SC),well graded sand <br /> (SW),and crushed stone classified as Poorly graded gravel(GP).The material shall be sampled in accordance with ASTM D5818 and load capacity. <br /> i86 7 <br /> measured in accordance with ASTM . <br /> 7.Resistance to toss of load capacity or Structural integrity when subjected to chemically aggressive environments measured via EPA 9090 immersion <br /> testing. <br /> Tensar Earth Technologies,Inc. <br /> 5883 Glenridge Drive,Suite 200 <br /> • Atlanta,Georgia 30328-5363 <br /> (800)836-7271 <br /> February 1,2004 <br /> This product specification supersedes allprior specifications for the product described above and is not applicable to any products shipped prior to <br /> February 1,2004. <br />