My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2013_8
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2013_8
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:43 PM
Creation date
7/3/2020 10:57:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2013_8
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2013_8.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
358
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Product Specification - Structural Geogrid UX1600HS <br /> ® Tensar Earth Technologies,inc.reserves the right to change its product specifications at any time. It is the responsibility of the specifier and purchaser to <br /> ensure that product specifications used for,design and procurement purposes are current and consistent with the products used in each instance. Please <br /> contact Tenser Earth Technologies,inc.at 800-836-7271 for assistance <br /> The structural geogrid shall be an integrally formed grid structure manufactured of a stress resistant high density polyethylene material <br /> with molecular weight and molecular characteristics which impart:(a)high resistance to loss of load capacity or structural integrity when <br /> the geogrid is subjected to mechanicak stress in installation;(b)high resistance to deformation when the geogrid is subjected to applied <br /> force in use;and(c)high resistance to!loss of load capacity or structural integrity when the geogrid is subjected to long-term <br /> environmental stress. <br /> The structural geogrid shall accept applied force in use by positive mechanical interlock(i.e.by direct mechanical keying)with:(a) <br /> compacted soil or construction fill materials;(b)contiguous sections of itself when overlapped and embedded in compacted soil or <br /> construction fill materials;and(c)rigid mechanical connectors such as bodkins,pins or hoops.The structural geogrid shall possess <br /> sufficient cross sectional profile to present a substantial abutment interface to compacted soil or particulate construction fill materials and <br /> to resist movement relative to such materials when subject to applied force. The structural geogrid shall possess sufficient true Initial <br /> modulus to cause applied force to.be transferred to the geogrid at low strain levels without material deformation of the reinforced structure. <br /> The structural geogrid shall possess complete continuity of all properties throughout its structure and shall be suitable for reinforcement of <br /> compacted soil or particulate construction fill materials to improve their long term stability in structural toad bearing applications such as <br /> earth retention systems. The structural geogrid shall otherwise have the following characteristics: <br /> Product Type: Integrally Formed Structural Geogrid <br /> Load Transfer Mechanism: Positive Mechanical interlock <br /> Product Properties <br /> Load Capacity Units MD Values' <br /> • True initial Modulus in Use2 kN/m(lb/R) 1,750(120,000) <br /> • Tensile Strength @5%Strain kN/mQb/ft) 58(3,980) <br /> • Ultimate Tensile Strenge? kN/m(ib/ft) 144(9,870) <br /> • Long-Term Allowable Load in Sands,Silts&Clay' kN/m(ib/ft) 59.9(4,110) <br /> • Long-Term Allowable Load in Well Graded Sandi kN/mQb/ft) 58.2(3,990) <br /> • Long-Term Allowable Load in Aggregate kN/m(ib/ft) 57.2(3,920) <br /> Integrity of Product Structure <br /> • Junction Strength" kN/m(lb/ft) 135(9,250) <br /> • Flexural Stiffnesss X1000 mg-cm 6,000 <br /> Durability <br /> • Resistance to Installation Damages %SC/%SW/%GP 95192/90 <br /> • Resistance to Long Tema Degradation' % 100 <br /> Dimensions and Delivery <br /> The structural geogrid shalt be delivered to the jobsite in roll form with each roil individually identified and nominally measuring 1.33 <br /> meters(4.36 feet)in width and 61.0 meters(200.0 feet)in length. A typical truckload quantity is 216 rolls. On special request,the <br /> structural geogrid may also be cust6m cut to spec lengths or widths to suit site specific engineering designs. <br /> Notes <br /> 1.Unless indicated otherwise,values shown are minimum average roll values determined in accordance with ASTM 13-47.59. Brief descriptions of test <br /> procedures are given in the following notes. Complete descriptions of test procedures are avalabie on request from Tensar Earth Technologies. <br /> Inc. <br /> 2.True resistance to elongation when initially subjected to a toad measured via ASTM 06637 without deforming test materials under bad before <br /> measuring such resistance or employing*secant"or"offset"tangent methods of measurement so as to overstate tensile properties. <br /> 3.True strength available for resisting force in tong-term load bearing applications is determined by reducing ultimate tensile strength by state-of- <br /> practice factors for installation damag6.degradation in use,product integrity limitations and long-term product deformation per GRI-GG4.. <br /> 4.Load transfer capability measured via GRI-GG2-87. <br /> 5.Resistance to bending force measured via ASTM D-5732-95,using specimen dimensions of 864 millimeters in length by 1 aperture in width. <br /> 6.Resistance to loss of bad capacity or Wructural integrity when subjected to mechanical Installation stress in clayey sand(SC),we#graded sand <br /> (SW),and crushed stone classified asipooriy graded gravel(GP).The material shall be sampled in accordance with ASTM D5818 and load capacity <br /> measured in accordance with ASTM 06637. <br /> 7.Resistance to loss of load capacity or Mructural integrity when subjected to chemically aggressive environments measured via EPA 9090 immersion <br /> testing. <br /> Tensar Earth Technologies,Inc. <br /> 5883 Glenridge Drive.Suite 200 <br /> ~® Atlanta.Georgia 30328-5363 <br /> (800)836-7271 <br /> February 1,2004 <br /> This product specification supersedes all'prior specifications for the product described above and is not applicable to any products shipped prior to <br /> February 1,2004. <br />
The URL can be used to link to this page
Your browser does not support the video tag.