Laserfiche WebLink
Water Quality Monitoring Report <br /> Forward Landfill <br /> leachate was observed at holding areas WMU D-89, WMU D-93/94, WMU D-04 N/S, and <br /> WMU D-02 and a total of 27,200 gallons of leachate was removed from the lined areas <br /> at an average rate of 299 gallons per day. For surface impoundment WMU-F (North), <br /> freeboard ranged from approximately 10.09 to 10.92 feet during the third quarter 2014 <br /> monitoring period. Appendix A presents copies of the leachate observation logs, <br /> freeboard observation logs, and dissolved oxygen measurements. <br /> Leachate samples are analyzed in the field for pH, specific conductance, temperature, <br /> and turbidity on a quarterly basis. Results of quarterly field monitoring measurements <br /> for the third quarter 2014 are presented in Table 2-6. <br /> 2.1.7 Surface Water Monitoring <br /> Site run-on and run-off control facilities are designed to effectively channel surface <br /> water to site stormwater/sedimentation ponds. According to the Operations Manager, <br /> there were no discharges from the Forward Unit to surface water (waters of the United <br /> States) during the reporting period. Surface water monitoring stations FSW-1 <br /> (downstream) and FSW-2 (upstream) were reported dry on August 25, 2014 during the <br /> third quarter 2014 monitoring period. As a result, no samples were collected. <br /> 2.2 Summary <br /> Groundwater quality conditions beneath the Forward Unit during the third quarter 2014 <br /> monitoring period are generally similar to those observed in previous monitoring <br /> periods. A non-statistical indication of release was identified at well MW-2A as a result <br /> of one VOC measured at a quantifiable concentration, and at well MW-17 as a result of <br /> two VOCs measured at estimated-trace concentrations. No other VOCs were detected <br /> in groundwater samples during the third quarter 2014 monitoring period. For the <br /> inorganic monitoring parameters, one or more CLs were exceeded at wells MW-1, MW- <br /> 2A, MW-10, MW-13, MW-15, MW-17, MW-19, and MW-24. Verification sampling for <br /> the organic and inorganic CL exceedances is scheduled for October 2014. During the <br /> monitoring period surface water sampling locations were reported dry. For vadose zone <br /> monitoring up to 14 VOCs were detected in soil-pore liquid samples and approximately <br /> 9600 gallons of liquid was pumped from pan lysimeter WMU-D01N. <br /> 3.0 AUSTIN UNIT <br /> 3.1 Water Quality Monitoring <br /> 3.1.1 Sampling and Laboratory Analyses <br /> Del-Tech performed routine monitoring of DMP, CAP, EMP wells at the Austin Unit <br /> during the third quarter 2014 monitoring period. Depth-to-water measurements were <br /> recorded in the groundwater monitoring wells on August 11 and 12, 2014. <br /> M:\2014.0012\FA_3Q14.docx 8 <br /> 10/31/2014,Rev.0 <br />