Laserfiche WebLink
Quarterly Progress Report — Second Quarter 2015 <br />Austin Unit. Forward Landfill Page 3 <br />volume), carbon dioxide concentration (percent by volume), balance gas (percent by volume), flow rate <br />(scfin), inlet pressure, outlet pressure, gas temperature at the inlet and outlet, and equivalent British <br />Thermal Units (BTUs) consumed. The landfill gas collection and destruction system undergoes <br />periodic maintenance to re -balance the collection vacuums to produce the highest percentage of landfill <br />gas (e.g., methane) and to minimize the collection of oxygen. <br />According to SCS Field Services, Inc., the landfill gas collection and destruction system experienced <br />the following periods of downtime during the second quarter 2015: <br />• May 5, 4:18 p.m. — 4:49 p.m.: Flare A-1 shut down for pre -inspection and cleaning for source <br />test. <br />• May 16,10:32 p.m. — May 18,10:12 a.m.: Flare A-2 shut down due to blower failure. <br />• May 26,11:35 a.m. — 3:13 p.m.: Flare A-1 shut down for cleaning of flame scanner. <br />• May 26,11:35 a.m. — 3:35 p.m.: Flare A-2 shut down for pre -source test. <br />• May 27, 7:31 a.m. —11:11 a.m.: Flare A-2 shut down for annual source test. <br />• May 27, 7:37 a.m. —11:05 am.: Flare A-1 shut down for annual source test. <br />Based on information provided by SCS Field Services, Inc., the landfill gas extraction and destruction <br />system operated at approximately 1,510 to 3,019 cubic feet per minute during the second quarter 2015. <br />This is equivalent to about 2,174,400 to 4,347,360 cubic feet per day. Based on the data presented in <br />the June 26, 2015 Annual Compliance Emissions Test Report prepared by Blue Sky Environmental, <br />Inc., Flare A-2 destroys an average of 20.1 lbs/hour of non -methane organics, and back-up Flare A-1 <br />destroys an average of 17.6 lbs/hour of non -methane organics. Non -methane organics are considered <br />equivalent to VOCs. During the period of April 1 through June 30, 2015, Flare A-2 operated <br />approximately 2,141 hours out of a possible 2,184 hours (98.0% operational rate). At the average VOC <br />destruction rate provided in the Source Test Report, Flare A-2 destroyed approximately 43,034 pounds <br />of VOCs during the second quarter 2015. <br />Attached is a copy of monitoring results for individual landfill gas extraction points during the second <br />quarter 2015 as provided by SCS Field Services, Inc. <br />If you have any questions, please contact Mr. Don Litchfield at (209) 982-4298. <br />Sincerely, <br />HERST & ASSOCIATES, INC. <br />Ward Herst, PG, HG Andrew Wyatt <br />Managing Partner Senior Environmental Scientist <br />cc: Erin Fanning — Forward, Inc. <br />Don Litchfield — Forward, Inc. <br />Bill Lopez — Geo -Logic Associates <br />Victoria Warren — Republic Services <br />