Laserfiche WebLink
Quarterly Progress Report - First Quarter 2016 <br />Austin Road Unit, Forward Landfill <br />According to SCS, the landfill gas collection and destruction system experienced 37.9 hours of <br />downtime during the first quarter 2016. A tabular summary of the downtime and the monitoring <br />results for individual landfill gas extraction points during the first quarter 2016 are presented in <br />Attachment C. <br />Based on information provided by SCS, the landfill gas extraction and destruction system operated <br />at approximately 1,564 to 2,091 cubic feet per minute during the first quarter 2016. This is <br />equivalent to about 2,252,160 to 3,011,040 cubic feet per day. Based on the data presented in the <br />June 26, 2015 Annual Compliance Emissions Test Report prepared by Blue Sky Environmental, Inc., <br />Flare A-2 destroys an average of 20.1 lbs./hour of non -methane organics, and back-up Flare A-1 <br />destroys an average of 17.6 lbs./hour of non -methane organics. Non -methane organics are <br />considered equivalent to VOCs. During the period of January 1 through March 31, 2016, Flare A-2 <br />operated approximately 2,146 hours out of a possible 2,184 hours (98% operational rate). At the <br />average VOC destruction rate provided in the Source Test Report, Flare A-2 destroyed <br />approximately 43,135 pounds of VOCs during the fist quarter 2016. <br />If you have any questions, please contact Mr. Joseph Lipka at (209) 982-4298. <br />Sincerely, <br />Geo -Logic Associates <br />William B. L z, PG, CHG <br />Senior Geologist <br />cc: Joseph Lipka - Forward, Inc. <br />Achaya Kelapanda - Forward, Inc. <br />Victoria Warren -Republic Services <br />Attachments: Groundwater Treatment System Monitoring Logs <br />Groundwater Treatment System Analytical Results <br />LFG Extraction Point Monitoring Results and Blower Flare Station Logs <br />Project No. 2016.0007 1 Quarterly Progress Report - First Quarter 2016 <br />April 2016 3 <br />v <br />n <br />