Laserfiche WebLink
STABILITY ANALYSIS <br /> WMU FU-17 FORWARD LANDFILL <br /> PROBLEM: <br /> Assess the static stability of the refuse over the lining system for WMU FU-17 at the Forward Landfill. <br /> Because WMU FU-17 is an interior module,there are no slopes on this module that will coincide with the <br /> final landfill grades. Seismic analyses are,therefore,not required. In addition,although there is a small <br /> lined area on the slope of the northwestern portion of the cell,refuse fill will overlie only a minor portion of <br /> this slope due to the geometry of the 3:1 northern refuse slope. Stability analyses on the interface liner on <br /> the northwest slope are,therefore,not required at this time. <br /> GIVEN: <br /> These calculations have been previously performed for the prior WMUs at the site and they have been <br /> found to have a satisfactory factor of safety and seismic deformation. The analysis for WMU FU-17 is <br /> similar to WMUs FU-03, ART-03,FU-04, FU-05,FU-06, FU-08,FU-10,FU-13,FU-14 and various other <br /> WMUs at the site. <br /> SUMMARY: <br /> 1. The planned maximum elevation of refuse in WMU FU-17,prior to the development of adjacent <br /> waste management units, is 170 ft MSL.This elevation is based on 3:1 slopes on the south and east. <br /> The west slope will be filled against the existing WMU FU-13 and 14 refuse slopes. <br /> 2. Development is planned to the east of WMU FU-14. In addition,the northern and southern boundaries <br /> are not extended to their full length to allow access to the wedge area on the south and a potential <br /> expansion to the north.These slopes are,therefore,temporary and will eventually be buttressed by <br /> adjacent slopes. <br /> STABILITY ANALYSIS SECTIONS AND CRITERIA: <br /> 1. The critical cross section for the stability analysis under the maximum interim filling configuration <br /> (refuse fill elevation 170 ft)is in the E-W direction along the base liner. <br /> 2. For interim slopes,a static factor of safety of 1.3 is typically considered acceptable. <br /> SUMMARY OF STABILITY ANALYSIS RESULTS <br /> 1. The minimum factor of safety for WMU FU-17 under the planned interim fill configuration(refuse <br /> elev. 170 ft)is 1.57. The critical failure surface extends from approximately the crest of refuse, <br /> through the refuse mass,and then along a portion of the base liner,daylighting at the toe of slope. <br /> Both the base liner interfaces(clay/HDPE and cushion geotextile/HDPE)were analyzed but the <br /> cushion geotextile/HDPE condition was found to be more critical. <br /> 2. The stability analysis assumes the base liner interface shear strengths between the clay and textured <br /> HDPE are a friction angle of 18 degrees and an apparent cohesion of 0 psf and a friction angle of 10 <br /> degrees and an apparent cohesion of 1,000 psf for normal load ranges from 0 to 6,500 psf and from <br /> 6,500 to 17,000 psf,respectively. The base liner interface strength between the cushion geotextile and <br /> the textured HDPE geomembrane is as follows: <br /> Normal Stress sf) Minimum Shear Stress(psf) <br /> 2,000 700 <br /> 4,000 1,110 <br /> 8,000 1,950 <br /> 12,000 2,780 <br />