Water Quality Monitoring Report <br />Forward Landfill <br />calculated for PCE at well AMW-12 (Table 2-5). Mann -Kendall trend analyses calculations are <br />presented in Appendix G. <br />3.1.5 Corrective Action/Evaluation Program <br />Field and laboratory results for CAP and EMP wells for the second quarter 2017 monitoring <br />period are summarized in Table 3-2. Excluding suspected laboratory contaminants, 17 of 28 <br />CAP/EMP wells reported one or more VOCs exceeding a Practical Quantitation Limit (PQL), with <br />CAP well AMW-22S having the highest total concentration of VOCs (94.46 Vg/L). An annual <br />report discussing the CAP and EMP monitoring results for the Austin Unit was prepared by Geo- <br />logic Associates (GLA, 2017) and reported under separate cover. <br />3.1.6 Cannery Waste Land Application Monitoring <br />Field and laboratory results for CWLAM wells for the second quarter 2017 monitoring period <br />are summarized in Table 3-4 and were compared to Water Quality Protection Standards (WQPS) <br />calculated for CWLAM constituents (total nitrogen, arsenic, iron, and manganese). As shown in <br />Table 3-4, no WQPS were exceeded. <br />3.1.7 Domestic Well Monitoring <br />Two domestic wells (8106-A and 7898-A) were sampled on May 24 and 30, 2017. Table 3-5 <br />summarizes the current analytical results for the domestic well samples collected. <br />Tetrachloroethene was measured above the PQL in both domestic well samples and DCDFM <br />and TCE were also measured above their PQLs in the sample collected from well 8106-A. <br />Estimated trace concentrations of two VOC (each) were also measured in the domestic well <br />samples. <br />3.1.8 Vadose Zone Monitoring <br />The current vadose-zone monitoring network at the Austin Unit consists of seven lysimeters. <br />The lysimeter locations are shown on Figure 3-1. As shown on Table 2-6A, with the exception <br />of FU -04W, all of the lysimeters were reported dry or had insufficient soil -pore liquid (5 <br />milliliters) for analysis. As shown in Table 2-66, only a trace concentration of 1,4-dichlobenzene <br />(1,4 -DCB) was measured in the soil -pore liquid sample collected from lysimeter FU -04W. <br />3.1.9 Leachate/Surface Impoundment Monitoring <br />For the Austin Unit, leachate sumps and surface impoundments are inspected weekly by <br />Forward Landfill personnel. If leachate is detected in a sump, it is pumped into the surface <br />impoundment WMU F (West) for evaporation. During the second quarter 2017, leachate was <br />observed at holding areas WMU FU -03, WMU FU -04, WMU FU -05, WMU FU -06, WMU FU -13, <br />and WMU FU -14 and a total of 694,600 gallons of leachate was removed from the lined areas at <br />v <br />Project No. 5017.1030 I Water Quality Monitoring Report 12 <br />July 2017 <br />