Laserfiche WebLink
Laboratories Inc. <br />Environmental Testing Laboratory Since 1949 <br />Geologic Associates Reported: 09/11/2017 14:51 <br />11415 W. Bernardo Ct, Ste 220 Project: Forward Landfill - Monthly A.S. Tower <br />San Diego, CA 92127 Project Number: August Monthly 2017 <br />Project Manager: Bill Lopez <br />Volatile Organic Analysis (EPA Method 82606) <br />Quality Control Report - Precision & Accuracy <br />Control Limits <br />Source Source Spike Percent Percent Lab <br />Constituent Type Sample ID Result Result Added Units RPD Recovery RPO Recovery Quals <br />The results in this report apply to the samples analyzed in accordance with the chain ojcustody document. This analytical report must be reproduced in its entirety. <br />All results listed in this report are for the exclusive use of the submitting party. BC Laboratories, Inc. assumes no responsibility for report alteration, separation, detachment or third party interpretation. <br />Report ID: 1000646506 4100 Atlas Court Bakersfield, CA 93308 (661) 327-4911 FAX (661) 327-1918 www.bclabs.com Page 11 of 12 <br />QC Batch ID: B[10683 <br />Used <br />client sample: <br />Y - Description: Air <br />Stripper Tower <br />Effluent Water, <br />08/31/2017 <br />13:14 <br />Benzene <br />MS <br />1724535-01 <br />ND <br />24.480 <br />25.000 <br />ug/L <br />97.9 <br />70-130 <br />MSD <br />1724535-01 <br />ND <br />24.110 <br />25.000 <br />ug/L <br />1.5 <br />96.4 <br />20 <br />70-130 <br />Bromodichloromethane <br />MS <br />1724535-01 <br />ND <br />28.970 <br />25.000 <br />ug/L <br />116 <br />70-130 <br />MSD <br />1724535-01 <br />ND <br />28.190 <br />25.000 <br />ug/L <br />2.7 <br />113 <br />20 <br />70-130 <br />Chlorobenzene <br />MS <br />1724535-01 <br />ND <br />25.740 <br />25.000 <br />ug/L <br />103 <br />70-130 <br />MSD <br />1724535-01 <br />ND <br />24.810 <br />25.000 <br />ug/L <br />3.7 <br />99.2 <br />20 <br />70-130 <br />Chloroethane <br />MS <br />1724535-01 <br />ND <br />23.140 <br />25.000 <br />ug/L <br />92.6 <br />70-130 <br />MSD <br />1724535-01 <br />ND <br />22.520 <br />25.000 <br />ug/L <br />2.7 <br />90.1 <br />20 <br />70-130 <br />1,4 -Dichlorobenzene <br />MS <br />1724535-01 <br />0.14000 <br />26.730 <br />25.000 <br />ug/L <br />106 <br />70-130 <br />MSD <br />1724535-01 <br />0.14000 <br />24.980 <br />25.000 <br />ug/L <br />6.8 <br />99.4 <br />20 <br />70-130 <br />1,1-Dichloroethane <br />MS <br />1724535-01 <br />0.13000 <br />24.890 <br />25.000 <br />ug/L <br />99.0 <br />70-130 <br />MSD <br />1724535-01 <br />0.13000 <br />24.070 <br />25.000 <br />ug/L <br />3.3 <br />95.8 <br />20 <br />70-130 <br />1,1-Dichloroethene <br />MS <br />1724535-01 <br />ND <br />26.600 <br />25.000 <br />ug/L <br />106 <br />70-130 <br />MSD <br />1724535-01 <br />ND <br />25.080 <br />25.000 <br />ug/L <br />5.9 <br />100 <br />20 <br />70-130 <br />Toluene <br />MS <br />1724535-01 <br />ND <br />27.420 <br />25.000 <br />ug/L <br />110 <br />70-130 <br />MSD <br />1724535-01 <br />ND <br />26.320 <br />25.000 <br />ug/L <br />4.1 <br />105 <br />20 <br />70-130 <br />Trichloroethene <br />MS <br />1724535-01 <br />0.23000 <br />27.700 <br />25.000 <br />ug/L <br />110 <br />70-130 <br />MSD <br />1724535-01 <br />0.23000 <br />27.330 <br />25.000 <br />ug/L <br />1.3 <br />108 <br />20 <br />70-130 <br />1,2-Dichloroethane-d4 (Surrogate) <br />MS <br />1724535-01 <br />ND <br />8.6600 <br />10.000 <br />ug/L <br />86.6 <br />75-125 <br />MSD <br />1724535-01 <br />ND <br />8.9200 <br />10.000 <br />ug/L <br />3.0 <br />89.2 <br />75-125 <br />Toluene -d8 (Surrogate) <br />MS <br />1724535-01 <br />ND <br />10.080 <br />10.000 <br />ug/L <br />101 <br />80-120 <br />MSD <br />1724535-01 <br />ND <br />10.090 <br />10.000 <br />ug/L <br />0.1 <br />101 <br />80-120 <br />4-Bromofluorobenzene (Surrogate) <br />MS <br />1724535-01 <br />ND <br />9.7400 <br />10.000 <br />ug/L <br />97.4 <br />80-120 <br />MSD <br />1724535-01 <br />ND <br />9.5000 <br />10.000 <br />ug/L <br />2.5 <br />95.0 <br />80-120 <br />The results in this report apply to the samples analyzed in accordance with the chain ojcustody document. This analytical report must be reproduced in its entirety. <br />All results listed in this report are for the exclusive use of the submitting party. BC Laboratories, Inc. assumes no responsibility for report alteration, separation, detachment or third party interpretation. <br />Report ID: 1000646506 4100 Atlas Court Bakersfield, CA 93308 (661) 327-4911 FAX (661) 327-1918 www.bclabs.com Page 11 of 12 <br />