Appendix A <br /> SAMPLING AND ANALYSIS PROCEDURES <br /> INTRODUCTION <br /> Ground-water monitoring program sampling and analytical procedures for <br /> the Landfill Development Site are contained in this appendix. The <br /> procedures, in accordance with Sections 2500 through 2601 of Subchap- <br /> ter 15, are recommended so that consistent and reproducible methods <br /> are used to obtain samples from monitoring wells and that proper <br /> analyses are performed on the samples. The sampling and analysis <br /> procedures used are based primarily on <br /> • Procedures Manual for Ground-Water Moni . ring at Solid <br /> Waste Disposal Facilities (U.S. EPA, EPA-530/SW-611, <br /> August 1977) <br /> • Test Methods for Evaluating Solid Waste: Phy icaL <br /> Chemical Methods (U.S. EPA, EPA SW-846, 3rd edition, <br /> November 1986) <br /> SAMPLE COLLECTION <br /> Sample collection procedures include equipment cleaning, water-level <br /> and total well depth measurements, well purging, sampling, and sample <br /> preservation and shipment. <br /> quipment Cleaning <br /> Sample bottles, bottle caps, and septa for use in sampling for vola- <br /> tile organics will be thoroughly washed with detergent, rinsed exten- <br /> sively with tap water, and then rinsed again with high purity deion- <br /> ized water. After washing and rinsing, sample bottles and bottle caps <br /> will be dried overnight at a temperature of 150°C. <br /> Sample bottles, bottle caps, and septa will be protected from all <br /> forms of solvent contact between the time of drying and actual usage <br /> PJ9 9390207.00D A-1 <br />