Laserfiche WebLink
corner of Section 21 (Arizuren property) in October 1980. The samples <br />were analyzed by Nelson Laboratories, and results are presented in <br />Appendix F. Results indicate that water from domestic and irrigation <br />wells on and adjacent to the proposed landfill site is within the <br />standards for drinking water as set by the U.S. Public Health Service <br />(see Table 4). <br />Ground -water quality at the proposed landfill site was also character- <br />ized by analyzing samples from the recently installed Monitoring <br />Wells G-1 and G-2 installed by EMCON during Spring 1987. To establish <br />baseline ground -water quality data for the site, EMCON analyzed these <br />samples for the following parameters: <br />• pH <br />• Electrical conductivity <br />• Total dissolved solids (TDS) <br />• Total organic carbon (TOC) <br />• Alkalinity <br />• Phenols <br />• Nitrate <br />• Chloride <br />• Total Kjeldahl nitrogen (TKN) <br />• Phosphate <br />• Volatile organics (EPA Method 624) <br />• Semivolatile organics (EPA Method 625) <br />• Chlorinated pesticides (EPA Method 608) <br />• 27 ICAP Metals <br />Analytical reports are summarized on Table 4 and contained in Appen- <br />dix F. In summary, analysis confirmed underlying ground water to be <br />of very good quality with no signs of existing contamination. <br />PJ9 9390206.000 14 <br />