Laserfiche WebLink
WASTE DISCHARGE REQUIREMENTS ORDER NO.R5-2002-0219 -5- <br /> FOR COUNTY OF SAN JOAQUIN <br /> FOR CONSTRUCTION AND OPERATION OF NORTH COUNTY RECYCLING <br /> CENTER AND SANITARY LANDFILL FACILITY, <br /> SAN JOAQUIN COUNTY <br /> 22. The direction of groundwater flow is toward the southwest. The average groundwater <br /> gradient is approximately 0.0004 foot per foot. The average groundwater velocity is <br /> 13.5 feet per year. <br /> 23. Monitoring data indicates background groundwater quality has an electrical conductivity <br /> (EC) ranging between 60 and 480 micromhos/cm,with total dissolved solids (TDS) <br /> ranging between 134 and 250 mg/l. <br /> 24. The designated beneficial uses of the groundwater, as specified in the Basin Plan, are <br /> domestic and municipal, agricultural, and industrial supply. <br /> GROUNDWATER, SURFACE WATER AND UNSATURATED ZONE MONITORING <br /> 25. The current groundwater monitoring system is comprised of an upgradient,background <br /> well G-1 and downgradient wells G-31), G-4, and G-5. The Discharger proposes to <br /> install a groundwater monitoring well G-6 downgradient from Module 4. <br /> 26. The current unsaturated zone monitoring system is composed of suction lysimeters <br /> strategically located beneath the landfill modules. VZ-1 is the background lysimeter <br /> located adjacent to G-1 on the upgradient(eastern) side of the facility. VZ-2 through VZ- <br /> 5 monitors Modules 1, 2, &3. VZ-6 though VZ-8 are proposed to be installed beneath <br /> Module 4; under the leachate sump (LZ-6),under one LCRS trench(LZ-7), and under the <br /> northeast portion of the base liner system(LZ-8). The secondary containment system <br /> beneath the leachate sump for Module 4 is identified as L-3. The lysimeters have access <br /> ports available at the surface for sampling of soil-pore liquids. <br /> 27. South Paddy Creek flows from north to south along the eastern boundary of the facility. <br /> The upgradient monitoring point in South Paddy Creek is S-1, and downstream <br /> monitoring point is S-2. S-4 surface water sampling point is located on the northwestern <br /> comer of the facility adjacent to Module 1 &2. S-4 monitors stormwater in a ditch that <br /> flows north along the perimeter of the facility boundary,which eventually flows to a <br /> wetlands area northeast of Module 1 &2. There is also a wetlands area west of S-1,north <br /> of the recycling center. A stormwater Retention Pond is located downgradient from the <br /> groundwater-monitoring well G-1 (upgradient) and west of S-2. Water from the <br /> Retention Pond is used for dust control and other activities on site. <br /> 28. The Discharger's proposed detection monitoring program for groundwater and soil-pore <br /> liquids in the unsaturated zone satisfies the requirements of Title 27. <br /> 29. The Discharger proposes to install a landfill gas (LFG)monitoring system beneath the <br /> single-composite liner as horizontal soil gas piping around the base of the perimeter and <br /> below the center of Module 4 to monitor the unsaturated zone for the presence of VOCs. <br /> Horizontal LFG collectors will also be installed in the first refuse lift, a minimum 15 feet <br />