Laserfiche WebLink
Table 2 EMCON <br /> Concentration Limits, MW-4 Project 939-03.18 <br /> Corral Hollow Sanitary Landfill 1st Quarter, 1995 <br /> Number of Mean, Standard Tolerance Lower Tolerance Upper Tolerance <br /> Samples, N x Deviation, s Factor, K Limit Limit <br /> Metals(mg/1) <br /> Aluminum, Dissolved 6 0.906 2.15 NA NA 0.05 [1] <br /> Antimony, Dissolved 7 0.034 0.033 NA NA 0.1 [1] <br /> Arsenic, Dissolved 7 0.005 0.005 NA NA 0.005[1] <br /> Barium, Dissolved 3 0.041 0.001 NA NA NA[2] <br /> Beryllium, Dissolved 3 0.003 0.002 NA NA NA[2] <br /> Boron, Dissolved 2 3.78 0.177 NA NA NA[2] <br /> Cadmium, Dissolved 7 0.003 0.002 NA NA 0.01[1] <br /> Chromium,Total Dissolved 7 0.014 0.020 NA NA 0.02[1] <br /> Chromium Hexavalent 5 0.005 0.001 NA NA 0.0115[1] <br /> Cobalt, Dissolved 3 0.006 0.004 NA NA NA[2] <br /> Copper, Dissolved 7 0.011 0.011 NA NA 0.005[1] <br /> Iron, Dissolved 21 0.930 2.666 2.371 NA 7.25 <br /> Lead, Dissolved 7 0.019 0.036 NA NA 0.005[1] <br /> Manganese, Dissolved 7 0.339 0.614 NA NA 0.005 [1] <br /> Mercury, Dissolved 7 0.00028 0.00015 NA NA 0.0005 [1] <br /> Nickel, Dissolved 7 0.008 0.008 NA NA 0.095[1] <br /> Selenium, Dissolved 7 0.007 0.012 NA NA 0.01 [1] <br /> Silver, Dissolved 7 0.005 0.003 NA NA 0.01 [1] <br /> Thallium, Dissolved 7 0.059 0.101 NA NA 0.005[1] <br /> Tin, Dissolved 3 0.028 0.021 NA NA NA[2] <br /> Vanadium, Dissolved 3 0.006 0.004 NA NA NA[2] <br /> Zinc, Dissolved[3] 7 -3.97 1.52 3.399 NA 3.35 <br /> NA=not applicable <br /> [1]=The upper tolerance limit was set at five times the method detection limit due to an insufficient number of detected values. <br /> [2]=Tolerance limits will be established following the attainment of four quarters of data. <br /> [3]=The W-test indicated that the analytical data for this parameter is lognormally distributed;the tolerance limit was set using lognormal data. <br /> In calculating tolerance limits, results below method detection limits were assigned values equal to half the method detection limit and <br /> "trace"values were assigned values equal to half the practical quanititation limit plus half the method detection limit. <br /> H:\exce1\corral\CAPMW-4.XLS Date Printed:4/21/95 <br />