Laserfiche WebLink
achieved solely through needlepunching, without any supplemental heat treatment. <br /> E. The GCL shall have 10,000-hour test data for large-scale constant-load (creep) shear <br /> testing under hydrated conditions. The displacement shall be 0.11 in. (2.7 mm) or less <br /> at a constant shear load of 250 psf(12 kPa) and a normal load of 500 psf(24 kPa). <br /> F. The GCL shall have seam test data from an independent laboratory showing that the <br /> seam flow with a grooved cut in the nonwoven geotextile is less than 1 x 10"$ m3/m2/s at <br /> 2 psi hydraulic pressure. <br /> G. The minimum acceptable dimensions of full-size GCL panels shall be 150 feet (45.7 m) <br /> in length. Short rolls [(those manufactured to a length greater than 70 feet (21 m) but <br /> less than a full-length roll)] may be supplied at a rate no greater than 3 per truckload or 3 <br /> rolls every 36,000 square feet (3,500 square meters) of GCL, whichever is less. <br /> H. A 6-inch (150 mm) overlap guideline shall be imprinted on both edges of the upper <br /> geotextile component of the GCL as a means for providing quality assurance of the <br /> overlap dimension. Lines shall be printed in easily visible, non-toxic ink. <br /> 2.2 Product Quality Documentation <br /> The GCL manufacturer shall provide the Contractor or other designated party with <br /> manufacturing QA/QC certifications for each shipment of GCL. The certifications shall be <br /> signed by a responsible party employed by the GCL manufacturer and shall include: <br /> A. Certificates of analysis for the bentonite clay used in GCL production <br /> demonstrating compliance with the swell index and fluid loss values shown in the <br /> Bentomat ST Certified Properties table. <br /> B. Manufacturer's test data for the finished GCL product demonstrating compliance <br /> with the values shown in the Bentomat ST Certified Properties table. <br /> C. GCL lot and roll numbers supplied for the project (with corresponding shipping <br /> information). <br /> Manufacturer's test data for finished GCL product(s), including GCL index flux, <br /> permeability and hydrated internal shear strength data, which demonstrate compliance <br /> with the performance.parameters shown in the Bentomat ST Certified Properties table, <br /> are available upon "request of the manufacturer. <br /> 2.3 Product Labeling <br /> A. Prior to shipment, the GCL manufacturer shall label each roll, identifying: <br /> 1. Product identification information (Manufacturer's name and address, brand <br /> product code). <br /> 2. Lot number and roll number. <br /> 2870 Forbs Avenue Hoffman Estates,'IL 60 .92 <br /> 847.851.1800;1 800.527.9948 <br /> www.CETCO.com <br />