My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
31130
>
4400 - Solid Waste Program
>
PR0440003
>
CORRESPONDENCE_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/27/2021 2:41:31 PM
Creation date
7/3/2020 11:04:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2011
RECORD_ID
PR0440003
PE
4434
FACILITY_ID
FA0003698
FACILITY_NAME
CORRAL HOLLOW LANDFILL
STREET_NUMBER
31130
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25303010
CURRENT_STATUS
01
SITE_LOCATION
31130 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440003_31130 CORRAL HOLLOW_2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
253
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the landfill in a northeasterly direction, with the largest concentrations measured at well <br />MW -5. The findings of direction and source of migration from this data is consistent <br />with the on-site monitoring results presented in previous reports. The locations of the <br />temporary wells did not allow for precise determination of the extent of VOC impacts. <br />As a result, additional investigation will be conducted by installing additional wells at <br />locations approved by RWQCB staff. <br />® The results of groundwater sampling and analysis of the three temporary wells <br />constructed as part of the EMP project suggest that the three temporary well sites are <br />within the VOC plume that extends to the north of the CHSL. In order to determine the <br />extent of the plume and fulfill that requirement of the EMP workplan, three additional <br />well locations are proposed. The "step -out" wells will be located where VOC <br />concentrations are estimated to be at non-detectable levels based on extrapolation of <br />the isoconcentration contours for Total VOCs. These three "step -out" wells will be <br />drilled, logged, and sampled in accordance with the methods outlined in the County's <br />EMP workplan dated August 2011, and approved by the RWQCB on August 25, 2011. <br />Once well construction is completed, a revised Well Installation Report will be prepared <br />and submitted to the RWQCB. Afterward, the findings and conclusions from the EMP <br />investigation will be compiled and presented to the RWQCB, followed by an EFS <br />outlining the County's proposed course of corrective action. <br />Well Completion Reporte ,C Page ■ 5 <br />Corral Hollow Sanitary Landfill w S E o c e AEE s <br />December 15, 2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.