Laserfiche WebLink
been reported in this well. Therefore, there has been no indication of impact from the landfill at <br />this well. <br />MW -7 (Up gradient): <br />Concentrations of all parameters were within established concentration limits where the limits <br />could be determined (Table 2). <br />No VOCs were reported at this well this quarter. VOCs were last detected in this well on <br />April 23, 2004; these detections are believed to have been introduced during well construction, <br />and do not indicate groundwater impact from the landfill. <br />Surface water <br />Surface water samples were not available during staff site visits this quarter due to lack of rain. <br />Such samples were last collected on January 27, 2011. All concentrations of field parameters and <br />constituents of concern were below established concentration limits where the limits could be <br />determined. <br />Unsaturated Zone Soil Pore Gas <br />The Monitoring and Reporting program for the landfill requires semi-annual VOC testing by TO - <br />15 analysis. Soil gas samples were collected on October 25, 2013, and are included in this fourth <br />quarter report. Before sampling, the concentration of major gasses (Methane, Carbon Dioxide, <br />and Oxygen) and pressure were measured using a CES-LANDTEC GEMTm2000 portable gas <br />detector. The GEMTm2000 was operated until a steady-state gas composition indicated that the <br />well was purged and ready for sampling. Soil gas samples were collected in 1 -liter Summa <br />canisters and sent for VOC analysis by EPA method TO -15. <br />The concentrations of major gasses were recorded during the fourth quarter 2013 TO -15 sampling <br />event, and a sample was collected from the probe most likely to have the highest VOC <br />concentration: the sample was taken from the probe with the highest methane content, but if <br />methane was not detected, the sample was collected from the deepest probe. The probe selected in <br />the first TO -15 sampling event conducted in 2006 has been used thereafter for this analysis. <br />Methane concentrations were zero in all perimeter migration monitoring wells during the fourth <br />quarter monitoring event. <br />VOCs were detected in all seven soil gas wells during the fourth quarter monitoring event. The <br />highest VOC concentration was found in well GW -61), however, there is no shallow aquifer at that <br />location. No "upwind" air sample was taken. <br />Concentrations of major gasses (Methane, Carbon Dioxide, and Oxygen) and pressure were <br />measured using a CES-LANDTEC GEMTm2000 portable gas detector on October 25, 2013. <br />Corral Hollow Sanitary Landfill 16 Department of Public Works/Solid Waste <br />4t" Quarter and Annual 2013 Groundwater Monitoring County of San Joaquin —January 15, 2014 <br />