Laserfiche WebLink
City of Stockton French Camp Landfill <br /> Groundwater Investigation <br /> Task 4 Deliverables <br /> No deliverables will be prepared specifically for submittal to the City. Data reports and laboratory <br /> QA/QC reports will be developed by the analytical laboratory. All sampling activities will be <br /> documented in field log books with chain-of-custody reporting completed in accordance with the <br /> established protocol. <br /> Task 5 —Analysis of Water Quality Data <br /> CDM will present the water quality data obtained during this investigation in a tabular format to <br /> clearly summarize the analytical results. In order to compare the interrelationships between the <br /> four zones under investigation,surface water,landfill leachate,intermediate groundwater zone, <br /> and deeper groundwater zone,Stiff Diagrams will be prepared for each monitoring point. Stiff <br /> Diagrams represent the chemical nature of the water(cation-anion relationships) in a graphical <br /> format. The diagrams can be compared against each other to assess interrelationships between <br /> water bodies. For example,if the landfill leachate Stiff Diagram is similar in shape to the <br /> intermediate zone diagram,then it can be concluded that the waters share similar character and are <br /> probably interconnected. This could indicate that a release of inorganic constituents has occurred <br /> from the site. Detections of VOCs in the downgradient wells would also suggest a release has <br /> occurred as defined in Article 5. <br /> Statistical analysis will be performed to compare the groundwater quality of the existing wells with <br /> proposed wells installed in adjacent locations. The purpose of this analysis is to determine if data <br /> from the current monitoring well network can be used on a long-term basis at the site. The results <br /> from these wells have been considered suspect because the wells are either screened through the <br /> landfill refuse or are screened near the influence of the sloughs. To test whether the data are <br /> useable,a statistical comparison can be made between the new wells,which will be installed in <br /> discrete zones,to the existing wells. If the results are statistically similar,and the Stiff Diagrams <br /> from the wells are also similar,it can be concluded that the wells are sampling the same water zone, <br /> and the data can be combined for future analysis. If the results are not similar,then it will be <br /> confirmed that the data from the existing wells is suspect and should not be used for quantitative <br /> analysis. <br /> Task 5 Deliverables <br /> Activities conducted under Task 5 will be documented in the Report of Findings described below. <br /> Task 6— Report of Findings <br /> The primary purpose of the Report of Findings(Report)is to document the activities associated <br /> with the groundwater investigation. These activities include the field work consisting of the <br /> monitoring well installation and water sampling,and the data evaluation and interpretation. The <br /> Report will present an opinion as to whether the landfill is leaking and whether preparation of the <br /> engineering feasibility study for corrective action should be performed. This determination requires <br /> a sufficient data base for a statistical analysis of the inorganic parameters and the presence of VOC <br /> contamination detected in the downgradient wells. <br /> CDM Camp Dresser&McKee 6 <br /> VMV,5 <br />