Laserfiche WebLink
Environmental Consultants 4707 Greenleaf Circle 209 545-8490 <br /> and Contractors Suite F FAX 209 545-8391 <br /> Modesto, CA 95356 www.sesfieldservices.com <br /> December 26, 2007 <br /> File No. 07206052.00 Task 1 <br /> Mr. Dan Johnson <br /> County of San Joaquin <br /> Post Office Box 1810 <br /> Stockton, California 95201 <br /> Subject: San Joaquin Valley Air Pollution Control District(SJVAPCD) Rule 4642 Surface <br /> Emissions Testing at the Harney Lane Landfill, Lodi, California <br /> Dear Mr. Johnson: <br /> This letter provides results of the November 14, 2007, SJVAPCD Rule 4642 landfill emissions <br /> monitoring performed by SCS Field Services (SCS) at the subject site. All work was performed <br /> in accordance with our County approved Work Scope (Task 1) contained in our proposal dated <br /> October 24, 2006. <br /> SUMMARY AND CONCLUSIONS <br /> On November 15, 2007, surface emissions testing showed no exceedences of the SJVAPCD <br /> Rule 4642 threshold limit of 1,000 parts per million by volume (ppmv). As stipulated in <br /> SJVAPCD Rule 4642, upon completion of two successive semi-annual tests without an <br /> exceedance of the 1,000 ppmv standard, other than non-repeatable momentary readings, the <br /> testing frequency may be decreased to once every calendar year. Based on these test results with <br /> no exceedance of 1,000 ppmv, no additional testing is required for a period of one year. <br /> Therefore, the next surface test event is due by the month of November 2008. <br /> BACKGROUND <br /> As you know, the Harney Lane site is a closed former organic refuse disposal site. By way of <br /> background, organic materials buried in a landfill decompose anaerobically (in the absence of <br /> oxygen) producing a combustible gas, which contains approximately 50 to 60 percent methane <br /> gas, 40 to 50 percent carbon dioxide, and trace amount of various other gases, some of which are <br /> odorous. The Harney Lane property contains a LFG collection and flare system to control the <br /> combustible gases generated in the landfill. <br /> The gases produced in a landfill will either vent vertically to the atmosphere or migrate <br /> horizontally through subsurface soil to locations on adjacent properties. If the soil surrounding a <br /> landfill consists of permeable materials, there is a greater likelihood that the LFG will migrate to <br /> off-site locations. If the methane gas component of LFG is allowed to accumulate in a confined <br /> area(i.e., utility lines, irrigation valve boxes, vaults,basements, wall spaces, etc.) and is exposed <br /> to an ignition source, it can be explosive at concentrations between 5 and ,15 percent by volume. <br />