Laserfiche WebLink
TABLE -2 <br /> LFG MIGRATION MONITORING WELL CONSTRUCTION DETAILS <br /> HARNEY LANE SANITARY LANDFILL <br /> LFG Well Probe Probe Pipe Sampling Bentonite Surface <br /> Migration Depth Pipe 2 Screened Interval Plug Elevation <br /> Monitoring Interval (Depth,FT) (Depth,FT) (MSL) <br /> Well No (FT) (Depth,FT) <br /> S 3to8 3to13 0to3 95 <br /> GW-1 59 1 18 to 23 18 to 33 13 to 18 <br /> D 38 to 43 38 to 59 33 to 38 <br /> S 3to8 3 to 13 0to3 95 <br /> GW-2 59 1 18 to 23 18 to 33 13 to 18 <br /> D 38 to 43 38 to 59 33 to 38 <br /> S 3to8 3to8 0to3 95 <br /> GW-3 44 1 13 to 18 13 to 23 8 to 13 <br /> D 28 to 33 28 to 44 23 to 28 <br /> S 3to8 3to8 0to3 95 <br /> GW-4 33 1 13 to 18 13 to 18 8 to 13 <br /> D 23 to 28 23 to 33 18 to 23 <br /> S 3to8 3to8 0to3 95 <br /> GW-5 33 1 13 to 18 13 to 18 8 to 13 <br /> D 23 to 28 23 to 33 18 to 23 <br /> S 3to8 3to8 0to3 95 <br /> GW-6 34 I 1 13 to 18 13 to 18 8 to 13 <br /> D 23 to 28 23 to 34 18 to 23 <br /> S 3to8 3to8 0to3 100 <br /> GW-7 44 1 13 to 18 13 to 23 8 to 13 <br /> D 28 to 33 28 to 44 23 to 28 <br /> S 3to8 3to8 0to3 100 <br /> GW-8 44 1 13 to 18 13 to 23 8 to 13 <br /> D 28 to 33 28 to 44 23 to 28 <br /> S 3to8 3to10 0to3 100 <br /> GW-9 44 1 15 to 20 15 to 21 10 to 15 <br /> D 26 to 31 26 to 44 21 to 26 <br /> Harney Sanitary Landfill San Joaquin County <br /> Landfill Gas Monitoring Plan 1 Department of Public Works <br /> Revised July 30,2009 Solid Waste Division <br />