ARCHIVED REPORTS_2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
14750
>
4400 - Solid Waste Program
>
PR0440007
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/14/2020 3:50:56 AM
Creation date
7/3/2020 11:09:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2009
RECORD_ID
PR0440007
PE
4434
FACILITY_ID
FA0000595
FACILITY_NAME
HARNEY LANE LANDFILL
STREET_NUMBER
14750
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06503006
CURRENT_STATUS
01
SITE_LOCATION
14750 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440007_14750 E HARNEY_2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
211
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
s <br /> San Joaquin_Valley <br /> Air Pollution Control District <br /> PERMIT UNIT: N-3303-1-1 EXPIRATION DATE: 08/31/2011 <br /> EQUIPMENT DESCRIPTION: <br /> LANDFILL GAS COLLECTION SYSTEM SERVED BY TWO HAUCK MANUFACTURING CO. BLOWERS RATED AT 500 <br /> SCFM EACH AND ONE 17 MMBTU/HR SUR-LITE MODEL MADISON LANDFILL GAS FIRED FLARE WITH A LANDFILL <br /> GAS CONDENSATE INJECTION SYSTEM <br /> PERMIT UNIT REQUIREMENTS <br /> 1. No air contaminant shall be released into the atmosphere which causes a public nuisance.[District Rule 4102] <br /> P <br /> 2. No air contaminant shall be discharged into the atmosphere for a period or periods aggregating more than three <br /> minutes in any one hour which is as dark as,or darker than, Ringelmann 1 or 20%opacity. [District Rule 4101] <br /> 3. Particulate matter emissions shall not exceed 0.1 grains/dscf in concentration. [District Rule 4201] <br /> 14. The gas collection system shall be operated in such a manner to prevent overdraw that can cause fires or damage to the <br /> gas collection system. [District Rule 4642] <br /> 5. Owner/operator shall maintain non-resettable,totalizing volumetric fuel flow meter that measures the daily quantity of <br /> landfill gas condensate injected. [District Rule 4642] <br /> Owner/operator shall maintain and operate the landfill gas flare in accordance with the manufacturer's specifications <br /> and in accordance with Section 5.2.4 of District Rule 4642(Solid Waste Disposal Sites). [District Rule 4642] <br /> 7. The thermocouple probe used to measure the flare temperature shall be located above the flame zone, a minimum of <br /> three(3) feet below the top of the flare shroud,and at least 0.6 second downstream of the burner. [District Rule 4642] <br /> 8. The flare shall be equipped with a temperature indicator,a gas flow indicator and a recorder that records the gas <br /> temperature in the flare stack, and the quantity of landfill gas consumed. The temperature and gas flow shall be <br /> recorded continuously while gas is flowing through the flare. [District Rule 4642] <br /> 9. A temperature of at least 1,475 degrees F,measured at the thermocouple probe, must be maintained when the flare is <br /> in operation. [District Rule 4642] <br /> 10. The methane content of the landfill gas shall not exceed 55%. [District Rule 2201] <br /> 11. The landfill gas condensate injection rate shall not exceed 0.6 gallon per minute. [District Rule 220 1] <br /> 12. Emissions from the flare shall not exceed any of the following limits: 0.06 lb-NOx/MMBtu, 0.0299 lb-SOx/MMBtu, <br /> 0.0425 lb-PM 10/MMBtu, 0.20 lb-CO/MMBtu, or 0.03 lb-VOC/MMBtu. [District Rule 2201] <br /> 13. The District shall be notified of any breakdown conditions in accordance with Rule 1100 (Equipment Breakdown). <br /> [District Rule 1100] <br /> 14. Owner/operator shall notify the APCO by telephone at least 24 hours before performing any maintenance that requires <br /> the system to be shutdown. The notification shall include a description of the maintenance, the date maintenance will <br /> be performed and the amount of time needed to complete the maintenance. [District Rule 4642] <br /> 15. During maintenance of the gas collection system or the flare,emissions of landfill gas into atmosphere shall be <br /> minimized during shutdown. The gas collection system and the flare shall not be shutdown for more than 144 <br /> cumulative hours in any calendar year. [District Rule 4642] <br /> 16. The destruction efficiency for non-methane hydrocarbons shall be at least 98% at all times. [District Rule 4642] <br /> PERMIT UNIT REQUIREMENTS CONTINUE ON NEXT PAGE <br /> These terms.and conditions are part of the Facility-wide Permit to Operate. <br /> Facility Name: SAN JOAQUIN CO.PUBLIC WORKS <br /> Location: 14750 F HARNEY LN.LODI,CA ; <br /> N-3303-1-1:Oct 202008 8:38AM—JOYT <br />