My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
3242
>
4400 - Solid Waste Program
>
PR0440068
>
COMPLIANCE INFO_2008-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2021 10:05:03 AM
Creation date
7/3/2020 11:10:21 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2017
RECORD_ID
PR0440068
PE
4434
FACILITY_ID
FA0001871
FACILITY_NAME
CALIFORNIA CLAY LANDFILL
STREET_NUMBER
3242
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
17702029
CURRENT_STATUS
02
SITE_LOCATION
3242 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\sfrench
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4434_PR0440068_3242 S EL DORADO_2008-2017.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IRON . Page 2 of 4 <br /> Inhalation: <br /> Remove to fresh air.Get medical attention for any breathing difficulty. <br /> Ingestion: <br /> Induce vomiting immediately as directed by medical personnel.Never give anything by mouth to an unconscious person.Get medical attention. <br /> Skin Contact: <br /> Wash exposed area with soap and water.Get medical advice if irritation develops. <br /> Eye Contact: <br /> Immediately flush eyes with plenty of water for at least 15 minutes,lifting upper and lower eyelids occasionally.Get medical attention if irritation persists. <br /> 5.Fire Fighting Measures <br /> Fire: <br /> Moderate fire hazard in form of dust when exposed to heat or flame.Can react with water to liberate flammable hydrogen gas.Minimum ignition temperature, <br /> iron dust cloud:430C(805F).Ultrafine iron powder(ca.5 microns)is pyrophoric and can ignite spontaneously in air. <br /> Explosion: <br /> Moderate explosion hazard in the form of a dust when exposed to heat or flame. <br /> Fire Extinguishing Media: <br /> Use powdered graphite,powdered salt,or powdered limestone.DO NOT use water,carbon dioxide,or dry chemical. <br /> Special Information: <br /> In the event of a fire,wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand <br /> or other positive pressure mode. <br /> 6.Accidental Release Measures <br /> Ventilate area of leak or spill.Wear appropriate personal protective equipment as specified in Section 8.Spills:Pick up and place in a suitable container for <br /> reclamation or disposal,using a method that does not generate dust. <br /> 7.Handling and Storage <br /> Keep in a tightly closed container,stored in a cool,dry,ventilated area.Protect against physical damage.Avoid dust formation and control ignition sources. <br /> Containers of this material may be hazardous when empty since they retain product residues(dust,solids);observe all warnings and precautions listed for the <br /> product. <br /> 8.Exposure Controls/Personal Protection <br /> Airborne Exposure Limits: <br /> -OSHA Permissible Exposure Limit(PEL)- <br /> Iron oxide fume:10 mg/m3 <br /> -ACGIH Threshold Limit Value(TLV)- <br /> Iron oxide dust and fume(Fe203)as Fe:5 mg/m3(TWA);inhalable particulate:A4-Not classifiable as a human carcinogen. <br /> Ventilation System: <br /> A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits.Local exhaust ventilation is <br /> generally preferred because it can control the emissions of the contaminant at its source,preventing dispersion of it into the general work area.Please refer to the <br /> ACGIH document,Industrial Ventilation,AManual of Recommended Practices,most recent edition,for details. <br /> Personal Respirators(NIOSH Approved): <br /> If the exposure limit is exceeded and engineering controls are not feasible,a full facepiece particulate respirator(NIOSH type N100 filters)may be worn for up to <br /> 50 times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier,whichever is lowest.If oil <br /> particles(e.g.lubricants,cutting fluids.glycerine,etc.)are present,use a NIOSH type R or P filter.For emergencies or instances where the exposure levels are <br /> not known,use a full-facepiece positive-pressure,air-supplied respirator.WARNING:Air-purifying respirators do not protect workers in oxygen-deficient <br /> atmospheres. <br /> Skin Protection: <br /> Wear protective gloves and clean body-covering clothing. <br /> Eye Protection: <br /> Maintain eye wash fountain and quick-drench facilities in work area.Use chemical safety goggles and/or full face shield where dusting or splashing of solutions <br /> is possible. <br /> 9.Physical and Chemical Properties <br /> Appearance: <br /> Gray crystalline chips. <br /> Odor: <br /> No information found. <br /> Solubility: <br /> Insoluble,can react with water. <br /> Specific Gravity: <br /> 7.86 @ 20C(6817) <br /> pH: <br /> No information found. <br /> Volatiles by volume @ 21C(70F): <br /> 0 <br /> Boiling Point: <br /> http://www.jtbaker.com/msds/englishhtml/i7500.ht 6/21/2010 <br />
The URL can be used to link to this page
Your browser does not support the video tag.