Laserfiche WebLink
The County Department of Public Works recommends that the improvements and permits within the City <br />of Manteca's portion of Louise Avenue be as required by the City. <br />The applicant has indicated that the loudest machine will not produce sound levels greater than 50 dB <br />at the property line. County noise performance standards require that sound levels be below 70 d13 at <br />the property line during the day and 65 dB during the night. In a graduated scale (see Table 9-1025.9 <br />of the Development Title, attached), noise levels at the property line may not exceed 50 dB for over 30 <br />minutes in any hour during the daytime and 45 dB for over 30 minutes in any hour during the nighttime. <br />The project must meet the County's noise performance standards. <br />The nearest noise receptors are the offices of the Manteca Unified School District located adjacent to this <br />site on the east. Other potentially sensitive noise receptors include residences to the northeast, east, <br />west, and the agricultural land to the south, which is designated for residential development in the City <br />of Manteca's General Plan. The nearest residence is approximately 1/3 mile from the existing buildings. <br />Projected 2005 noise contours for Louise Avenue indicate 70 dB CNEL at 123 feet from the edge of <br />pavement. Because this project must meet County noise performance standards, and because this <br />project is not likely to produce noise greater than the noise from Louise Avenue, this project is not <br />expected to have a significant noise impact. <br />- Dust/Air Qualily <br />Because all processing must be done indoors, dust will be kept to a minimum. The vermiculture operation <br />and wholesale nursery require moisture and are not likely to generate significant- levels of dust. Parking <br />and major circulation areas will be paved. Trailer storage areas will be graveled, and minor use areas will <br />be chip sealed. The San Joaquin Valley Unified Air Pollution Control District noted that a Negative <br />Declaration is appropriate from an air quality perspective. The District noted that air impacts will be <br />associated with the construction phase of the project and provided the applicant with applicable <br />regulations. <br />Ri (01 d I ETF <br />The applicant is proposing natural or existing drainage. The applicant has indicated that some of the <br />drainage now flows into the South San Joaquin Irrigation District Drainage Canal on the west side of the <br />project site. The District has stated that the applicant will not be allowed to discharge drain water of any <br />kind into District facilities without approval of the District. The applicant has been informed that obtaining <br />approval from the District is not assured. If terminal drainage is not available, any increase in drainage <br />caused by new development shall be retained on the site. <br />San Joaquin County UP-95-8/Rouse <br />Community Development Page 6 <br />