DIRECTIONS FOR FILLING OUT CIWMB-53 FORM
<br />Fill out inspection form completely. Mark the lines to the right of each law or regulation with one of the following codes:
<br />V = Violation C = Compliance A/C = Area of Concern N/A = Not Applicable N = Not Evaluated
<br />Summarize inspection results in the COMMENTS section. If additional space is required, use form SWIS-03. Include explanations for determinations of N/A or N when
<br />appropriate. Check form(s) for completeness/accuracy and submit to the California Integrated Waste Management Board within 30 days of the inspection in accordance
<br />with 30 PRC 43218.
<br />PARTIAL SUMMARY OF APPLICABLE LAWS AND REGULATIONS
<br />Consult Title 14, California Code of Regulations, and the Public Resources Code for the complete laws and regulations listed on this form.
<br />PRC 44004 -No significant change in design or operation except in conformance with approved solid waste facilities permit (SWFP). Application filed with LEA for
<br />modifications in design or operation of facility at least 120 days in advance of date proposed modification to take place.
<br />LARGE VOLUME
<br />17441 -Amendments to RSI filed to keep information current. 17442 -Enforcement agency notified of significant changes in the design or operation of the station.
<br />17451 -Design of new facility shall utilize expert advice. 17452 -Station design shall be based on appropriate data, take account of features needed to accomodate public use.
<br />17453 -Station designed to minimize nuisances and detrimental effects to public health and the environment. 17461 -Accurate weight/volume records maintained in a
<br />manner and form approved by the LEA. 17462 -Log of special occurrences maintained (fires, injury and property damage accidents, explosions, incidents regarding
<br />hazardous waste, flooding, and other unusual occurrences). 17463 -Records available for inspection.
<br />17471 -Adequate number of qualified personnel available. 17472 -Personnel adequately trained. 17473 -Adequate supervision provided. LEA and appropriate fire control
<br />authority advised of names, addresses, and telephone numbers of operator, station manager, and site supervisor. 17474 -Attendant available full-time or as determined by
<br />LEA.
<br />17481-I.D. signs at each point of access indicating name of station operator. Other information may be required by LEA. 17482 -Entry sign located at appropriate point
<br />states fees, hours of operation, wastes accepted or not accepted. 17483 -Adequate perimeter security. Hazardous areas fenced and identified.
<br />17484 -Roads have smooth surface, minimize dust and tracking of mud, and allow all-weather access.
<br />17485 -Visual screening provides attractive appearance as approved by LEA and local land use authority. 17486 Waste bins are durable, easily cleanable, safe and leak-
<br />proof. Tipping areas safe, easily cleanable, and designed to prevent the loss of waste. All station equipment in good condition and cleaned in frequency and manner to
<br />prevent vectors and other nuisances.
<br />17491 -Adequate sanitary facilities available at station or immediate vicinity. 17492 -Safe adequate drinking water available.
<br />17493 -Communication facilities adequate. 17494 -Adequate lighting as approved by LEA.
<br />17495 -Sufficient fire fighting equipment available and located as required by local fire authority and LEA. 17496 -Contact between users and wastes minimized. Barriers
<br />provided as necessary. 17497 -Safety equipment in use and being worn as required by LEA.
<br />17511 -Unloading adequately confined. Wind-blown materials adequately controlled. 17512 -Daily cleaning of loose materials and litter, or as approved by LEA.
<br />17513 -Wastes removed every 48 hours or as approved by LEA. 17514 -Uncleaned or fully loaded transfer vehicles must not be parked on public streets or roads except
<br />under emergency conditions.
<br />17515 -Scavenging prohibited. 17516 -Salvaging must not interfere with operations. 17517 -Volume reduction operations minimize health, safety, and nuisance problems;
<br />does not interfere with operations. 17518 -Salvaging and volume reduction confined to clearly identified areas. 17519 -Processing operations are conducted in an organized
<br />manner and minimize health, safety, and nuisance problems. 17520 -Salvage storage location acceptable. Volume as approved by LEA, minimizes vectors, fires,
<br />nuisances, or other hazards. 17521 -Salvage storage time does not result in health or fire problems. 17522 -Salvaged materials approved by LEA and local health authority.
<br />17531 -Operations do not create a public nuisance. 17532 -Dust control adequate. 17533 -Vector and bird vontrol adequate.
<br />17534 -Drainage as approved by LEA. Coordinated with RWQCB. Connection to sewer prohibited unless approved by local sewerage authority.
<br />17535 -Litter control adequate. 17536 -Noise control adequate. 17537 -Odor control adequate. 17538 -Traffic control adequate into and within site. Traffic minimizes
<br />interference, safety problems, and stacking on public roads.
<br />17546 -Equipment adequate in type, capacity, and number, and is adequately maintained. 17547 -Standby equipment available. 17548 -Transfer vehicles adequately
<br />covered and constructed of durable, easily cleanable materials. 17549 -Equipment used for transport of solid wastes available for inspection.
<br />17550 -Equipment housekeeping adequate.
<br />17556 -Effective maintenance procedures and programs developed and utilized. 17557 -Adequate monitoring and repair of deteriorated conditions.
<br />17561 -Burning wastes immediately spread and extinguished in safe area. 17562 -Site accepts approved hazardous wastes only and handling complies with Chapter 2, Div.
<br />4, Title 22, CAC. 17563 -Infectious wastes adequately processed to eliminate any hazard. 17564 -Liquid wastes handled with proper equipment and authorized by
<br />RWQCB, local health entity, and LEA.
<br />18213(b) -Permit review application submitted no less than 120 days before SWFP is due for review. 18221 -RSI content requirements complete.
<br />SMALL VOLUME
<br />17422 -Engineering design of proposed new small volume transfer stations in accordance with generally accepted principles and disciplines, submitted to LEA for review.
<br />17423 -Plan of Operation submitted to LEA summarizing procedures for handling complaints, maintenance, health and safety, site controls, and frequency of waste removal.
<br />17424 -Annual report to LEA reporting weights/volumes handled during previous year and listing special occurrences (fires, injury, property damage, accidents, explosions,
<br />incidents regarding hazardous wastes, flooding, and other unusual occurrences). 17425 -Minimal public health and safety hazards, vector and bird control adequate, waste
<br />materials adequately contained, litter control adequate, drainage control adequate, and nuisance control adequate. 17426 -Station cleaned and wastes removed weekly or as
<br />approved by LEA. 17441 -Amendments to Plan of 00
<br />on filed to keep information current. 0
<br />
|