Laserfiche WebLink
APPENDIX I <br />Management: PCB Capacitors will be transported to the San Joaquin County <br />Household Hazardous Waste Facility for appropriate disposal as a <br />CESQG waste. <br />Non -PCB Capacitors <br />Packaging: 55 gallon drum <br />Labeling: Used oil -containing Capacitors <br />Management: Non -PCB containing capacitors are sent to ECS refining for <br />recycling. <br />Downstream Vendors/Disposal Facilities <br />Staffing <br />Onsite's CAR certified staff are responsible for all appliance recycling operations. In <br />addition to EPA Refrigeration Technician Certification, all CAR technicians receive the <br />following Appliance -specific training: <br />• Identifying unit and refrigerant type <br />• Freon Removal Procedures <br />• Compressor Oil Removal Procedures <br />• Mercury Switch Identification and Removal <br />• Capacitor removal <br />• PCB Capacitor Identification <br />• Material Packaging Requirements <br />• Labeling Procedures <br />• Transportation Requirements <br />• CESQG Requirements <br />Page 3 of 7 <br />