Laserfiche WebLink
III. ENVIRONMENTAL SETTING,IMPACTS AND MITIGATION MEASURES <br /> D. NOISE <br /> TABLE IIID-6 <br /> AFFECT OF PROJECT OPERATIONS ON OVERAL DNL VALUES AT ADJACENT <br /> RESIDENCES ON TEMPLE STREET <br /> (ALL VALUES SHOWN IN TERMS OF DNL) <br /> Noise Level in dBA <br /> Existing+ Existing+ <br /> Project(w/ Project(w/ <br /> 6-foot wall+ 10-foot wall+ <br /> Existing+ hourly limits on hourly limits on <br /> Project green waste green waste <br /> Receptor Location Existinga (no mitigation)b operations)c operations)c <br /> Residences on Temple Street Weekdays 66 68 66 66 <br /> Weekends 61-64 65 61 61 <br /> a Range of DNL values measured over four-day period(see Table III.D-2). <br /> b Calculations logarithmically add together existing measured noise levels plus the hourly Leq values shown in <br /> Table III13-5 during operating hours. <br /> c The effectiveness of a 6-foot wall and 10-foot wall are the same as calculated in Table IIID-5. Calculations also <br /> assume that greenwaste processing activities would be limited to after 7:00 a.m. See Tables A-7 and A-8 in <br /> Appendix A. <br /> Mitigation Measures Proposed as Part of the Project <br /> Mitigation Measure D.2a: Implement Mitigation Measure A.1a(limitations on Sunday <br /> operations). <br /> Mitigation Measures Identified in This Report <br /> Mitigation Measure D.2b: Implement Mitigation Measure III.AIc(construction of a 6- <br /> foot solid masonry wall along the western boundary of the site). <br /> Mitigation Measure D.2c: Limit greenwaste processing activities to between the hours of <br /> 7:00 a.m. and 5:00 p.m. This would limit the project's most pervasive noise source to the <br /> least noise-sensitive hours of the day. <br /> Mitigation Measure D.2d: The tub grinder should be located such that itself and <br /> associated equipment would be operated at a minimum of 75 feet from the site's eastern <br /> and southern boundaries with adjacent industrial properties. <br /> Mitigation Measure D.2e: The project applicant shall erect a noise barrier around the <br /> eastern and southern boundaries of the green waste processing area. The barrier should be <br /> designed such that the line of sight of the tub grinder and associated equipment is blocked <br /> from view from industrial uses. The structure shall be constructed of materials that would <br /> effectively reduce noise levels by a minimum of 10 dBA at off-site receptor locations. <br /> Significance After Mitigation: As shown in Table A-9 of Appendix A, a combination of the <br /> above measures would reduce the overall DNL on industrial properties to a level that is <br /> Stockton Scavenger Transfer Station 61cpansion III.D.17 ESA 1990190 <br />