TABLE 5-1 <br /> BASIC DESIGN PARAMETERS - <br /> PACKAGE INCINERATOR/POWER PLANTS <br /> Item Value <br /> Trommel Spilt (Throughout/Dropout) (Wt.) 50%/50% <br /> Fuel Product Moisture Content (Wet Basis) 30% <br /> Fuel Product Heating Value Btu's/lb. 7,000 <br /> (Moisture-Free Basis) <br /> Ash Content of Fuel Product 13% <br /> (As Received) <br /> Thermal Efficiency 62% <br /> Steam: <br /> Output 2.6 lbs./lb. of refuse fuel <br /> Pressure 450 psi <br /> Temperature 7250 F <br /> Turbine Steam Rate 12.5 lbs. steam/kwh <br /> Ferrous Recovery Efficiency 50% <br /> Recovered Products <br /> The resource recover plant, as conceptualized, will <br /> Y P p recover fer- <br /> rous metals and produce either steam or electric power. Based on <br /> the refuse quantity and composition established in Chapter 2 and <br /> the design parameters listed in Table 5-1, the following product <br /> quantities can be recovered: <br /> 1. Ferrous metals - 3 , 500 tons per year <br /> - and - <br /> 2. a. Steam - 260 , 000 , 000 pounds per year at 450 psi , <br /> 7250 F <br /> - or - <br /> b. Electricity - 21,000 ,000 kilowatt-hours per year <br /> at 13 , 800 volts. <br /> 30 <br />