Laserfiche WebLink
Alternative 5--Enclosed Agitated Bed/Windrow <br /> Use compost areas C1 and C2 for enclosed agitated bed and areas C3 through C8 for windrows <br /> Agitated bed capacity <br /> Use IPS for a basis of sizing <br /> Assume the following: <br /> Bay width 10 feet <br /> Bay depth 5.5 feet <br /> Bay lengthl 200 feet <br /> Volume per bay 407 CY <br /> Number of bays <br /> Phase 1 14 5,704 CY <br /> Phase 11 17 6,926 CY <br /> Total 31 12,630 CY <br /> Width Length Area <br /> (ft) (ft) (acres) <br /> C1 400 230 2.11 <br /> C2 400 260 2.39 <br /> Total 4.50 <br /> Windrow capacity from Alternative 2 <br /> C3 7 windrows 275 feet long 5,704 CY <br /> C4 7 windrows 200 feet long 4,148 CY <br /> C5 20 windrows 200 feet long 11,852 CY <br /> C6 20 windrows 200 feet long 11,852 CY <br /> C7 8 windrows 110 feet long 2,607 CY <br /> C8 8 windrows 200 feet long 4,741 CY <br /> Total 40,904 CY <br /> FN:dtr/a:\COMPVOL.XLS Page 4 of 4 Printed: 9/2/94 12:17 PM <br />