Laserfiche WebLink
Alternative 5—Enclosed Ac <br /> -jhated BedfWindrow <br /> Use compost areas C1 and C2 for enclosed agitated bed and areas C3 throe GB for windrows <br /> Agitated bed ca aci <br /> Use IPS for a basis of sizing <br /> Assume the folloyla. <br /> Bay width 10 feel: <br /> Ba depth 5_.5 feet <br /> Bay Pen th 200 f P,e i: <br /> Volume per bay 407_CY <br /> — Number of bays <br /> Phase 1 14 5,704 CY <br /> Phase 11 17 6,926 CY <br /> Total 31 12,630 CY <br /> Width 'Len��7_Area <br /> (acres) <br /> 400 230 2.11 <br /> C2 _400_ 260 2.39 <br /> Total 4.50 <br /> Windrow capacity from Alternative 2 <br /> C3 7 windrows 275 feet long 5,704 CY <br /> C4 7 windrows 200 feet long 4,148 CY <br /> C520 windrows —200 feet In 11,852 I.Cy <br /> G6 20 windrows 200 feet long 11,852 CY <br /> C7 8 windrows 116 feet long 2,607 CY <br /> C8 8 windrows 200 feet long 4,741 CY <br /> Tatal 40,904 CY <br /> FN:dtr/a.\COMPVOLXLS Page 4 of 4 Printed:912194 12:17 PM <br />