My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GUILD
>
715
>
2200 - Hazardous Waste Program
>
PR0524006
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 2:29:29 PM
Creation date
7/6/2020 11:53:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0524006
PE
2227
FACILITY_ID
FA0016140
FACILITY_NAME
LUSTRE CAL NAMEPLATE CORPORATION
STREET_NUMBER
715
Direction
S
STREET_NAME
GUILD
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
04931024
CURRENT_STATUS
01
SITE_LOCATION
715 S GUILD AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Tank and Secondary Containment Assessment Irerracon <br /> Lustre-Cal Facility Lodi, CA <br /> April 22, 2019 Terracon Project No. NA197014 <br /> Tank Lateral Load Calculations' <br /> ASCE 7-10, Section 15.4.1 <br /> Table 15.4.2 <br /> R = 2.5 <br /> Qo = 2.0 <br /> Cs = 0.044xSDS x1 = 0.044x0.59x1.0 = 0.026, use 0.03 <br /> Tanks 3 through 5: <br /> 48" tall, 38" dia., 200 gal <br /> W (lb) = 200 gal = 26.7 ft3 x 62.4 pcf= 1668 Ib <br /> Vhoriz = 0.03 x W = 0.03 x 1668 Ib = 50 Ib <br /> overturning = (50 lb x 2 ft)-(0.6 x 1668 lb x 1.58 ft) _ _4671b <br /> 3.17 ft <br /> Friction = 0.3 <br /> FF = 1668 lb x 0.3 = 500 lb > 50 lb <br /> Tanks 6 through 10: <br /> 70" tall, 48" dia., 540 gal <br /> W (lb) = 540 gal = 72.2 ft3 x 62.4 pcf= 4505 Ib <br /> Vhoriz = 0.03 x W = 0.03 x 4505 Ib = 135 Ib <br /> overturning = (135 lb x 2.92 ft)-(0.6 x 4So51b x 2 ft) _ 12521b <br /> Friction = 0.3 <br /> FF = 4505 Ib x 0.3 = 1352 Ib > 135 Ib <br /> Tank Assessment Conclusions: <br /> From our tank assessment, we have concluded that the tanks, secondary containment, and <br /> overall ancillary piping and equipment are in good condition. No leaks or repairs requiring <br /> attention were noted during on-site inspection. All seismic calculations show that the lateral <br /> seismic restraint of the tanks are acceptable and have been designed correctly. <br /> ' American Society of Civil Engineers 7-10,Minimum Design Loads for Buildings and Other Structures, Section <br /> 15.4.1 <br /> Responsive ■ Resourceful ■ Reliable <br />