Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KETTLEMAN CHEVRON 601 E KETTLEMAN LN, LODI July 21, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 202 CCR 2715(c)(3), 2715(c)(4) Failure to maintain the"Facility Employee Training Certificate"on-site(after October 1, <br /> 2018). <br /> OBSERVATION: The"initial training dates" listed for the employees were after the"date of assuming responsibility <br /> as a facility employee"in the Facility Employee Training Certificate dated 1/12/2020,4/8/2020, and 5/26/2020. <br /> -The initial training dates are not accurate and are the same as the date of training; several of the employees are <br /> listed as having received training on previous training logs. <br /> -The date of assuming responsibility as a facility employee is only listed as the year and not the full date. <br /> REGULATION GUIDANCE:All site employees must be trained prior to taking responsibility as a facility employee if <br /> after October 1, 2018, or within 30 days of hire if prior to October 1, 2018. The Facility Employee Training <br /> Certificate shall contain accurate information for all employees trained. <br /> CORRECTIVE ACTION: Update the Facility Employee Training Certificate to contain the accurate information and <br /> submit a copy of the updated form to the EHD. <br /> This is a minor violation. <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days. <br /> 1)OBSERVATION:The designated operator failed to check and note all required items on the visual inspection <br /> reports.The incorrect and missing information included the following from the inspection reports: <br /> -The designated operator answered the question regarding sump sensor locations but did not list which sumps <br /> were visually inspected. <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> 2)OBSERVATION:The designated operator failed to check and note the correct test dates for the secondary <br /> containment testing on the designated operator inspection reports. Secondary containment testing was performed <br /> on 1/22/2018. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0003803 PR0231348 SCO01 07/21/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />