PE
2361
FACILITY_ID
FA0000508
FACILITY_NAME
7-ELEVEN INC #17647
STREET_NUMBER
1048
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
21903003
CURRENT_STATUS
01
SITE_LOCATION
1048 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> T-1 T-2 <br /> Tank ID (one OPE per column) <br /> Are both vent and tank riser piping Yes r; Yes r' Yes Yes <br /> secondarily contained? r No r No r No r No <br /> OPE Model oPw oPw <br /> V Shut off P Shut off Shut off Shut off <br /> Flow Flow Flow Flow <br /> Restricts ! Restricts ! Restricts ! Restricts <br /> What is the OPE response when activated? Flow Flow Flow Flow <br /> (Check all that apply) Audible ' Audible ' Audible ' Audible <br /> Alarm Alarm Alarm Alarm <br /> Visual ! Visual ! Visual ! Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping r Yes* r Yes* r Yes* r Yes* <br /> that may interfere with the OPE operation? No r: No r No r No <br /> At what level in the tank is the OPE set to <br /> activate? (Inches from bottom of tank) 80.25 79.75 <br /> What is the percent capacity of the tank at 94.8% 94.4% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to Yes Yes r Yes r Yes <br /> respond when the stored substance reaches r No r No r No r No <br /> the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> Pass Pass r Pass r Pass <br /> OPE Inspection Results Fail r Fail r Fail r Fail <br /> 8. COMMENTS <br /> Describe all results marked "Fail"and each proposed remedy. <br /> *Mark here if: <br /> Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br />
The URL can be used to link to this page
Your browser does not support the video tag.