My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
205
>
2300 - Underground Storage Tank Program
>
PR0232257
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2020 6:35:43 PM
Creation date
7/6/2020 1:03:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0232257
PE
2361
FACILITY_ID
FA0000670
FACILITY_NAME
QUIK STOP MARKET #3148*
STREET_NUMBER
205
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04116115
CURRENT_STATUS
01
SITE_LOCATION
205 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
95
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PREVENTIVE MAINTENANCE Good Valve <br /> Annually, inspect the flapper in the 71 SO to see that it is Deflection Shield <br /> open by looking down the drop tube opening (see in - with Poppet <br /> spection procedure below) . Test the 71 SO drop tube protected <br /> seals with CARB procedure TP-201 . 1 D . If the drop tube <br /> seal passes testing , no further maintenance is required . <br /> If the drop tube fails testing, replace the drop tube seal <br /> with OPW P/ N : H11931 M for 4" Tubes . Re-test the 71 SO <br /> drop tube with CARB procedure TP-201 . 1 D . The lower <br /> tube o-ring seal OPW P/N : H14840M can also be re - _ <br /> placed . If this does not correct the leak the 71 SO needs <br /> to be replaced . Bad Valve <br /> FOR TESTABLE MODELS ONLY : The socket adaptor Deflection Shield <br /> can be removed and poppet and float movement and with Poppet exposed <br /> function inspected without removing the valve . See <br /> Page 17 for full testing details . If replacement parts are <br /> needed for testable models the following items are ti 't <br /> available: OPW P/ N 206741 Testable Inlet Tube S/A, <br /> 206740 Socket Adaptor and Cable Assembly, and 61 SOK <br /> -0001 Float Kit. <br /> j Figure 27 <br /> CAUTION : Do not insert any foreign object into drop <br /> tube if flapper is in the closed position . For exam - Note: Figure 27 shows poppet location with float arm <br /> pie, a tank level measuring stick. This will damage not activated . <br /> the valve and void the Warranty. ALWAYS check <br /> flapper location before "sticking " the tank. If flap- INSP 4. Inspect the float by lifting upward . The float <br /> per is in the closed position, the tank is either over- should move freely without any binding . See Figure <br /> filled and you need to wait until the liquid level goes 28o <br /> down or the 71 SO is damaged and needs to be re- _ <br /> placed . hell <br /> Inspection Procedure to Ensure Proper Operation <br /> Note: For testable models valve does not need to be <br /> removed from tank. See page 17 for testable instruc- I == <br /> tions . <br /> INSP 1 . Remove the overfill valve from the tank as de- _ <br /> scribed in step 26 . Float <br /> INSP 2 . Visually inspect the valve for damage. Make <br /> sure no debris or foreign objects are in or on the valve . ' <br /> INSP 3 . With the float in the normal (down ) position, Figure 28 <br /> visually inspect the valve to ensure the poppet is not <br /> exposed outside the deflection shield . See Figure 27 . INSP S . View down the tube to ensure the poppet is <br /> moving into the flow path when lifting the float. See <br /> Figure 29 . <br /> 18 <br />