Laserfiche WebLink
' Additional Site Assessment and Soil Vapor Extraction Pilot Test Report <br /> ERNIE'S GENERAL STORE <br /> ' 4407 East Waterloo Road, Stockton, California <br /> ' 1.0. INTRODUCTION <br /> At the request of Mr.Ernest P.Giannecchini,AdvancedGeoEnvironmental,Inc.(AGE)has prepared <br /> ' this report of environmental activities conducted at the site located at 4407 East Waterloo Road, <br /> Stockton, California. The report documents the following environmental activities conducted in <br /> November and December 2006: <br /> • On 22 November 2006,two paired CPT soil borings were advanced to further delineate the <br /> lateral and vertical extents of hydrocarbon-impacted soil and ground water at the site. <br /> ' 0 On 14 December 2006, one additional shallow ground water monitoring well was installed <br /> on the property located at 4318 East Pepsi Place, Stockton, California, approximately <br /> ' 250 feet west of the site,to verify and monitor the eastern boundary of the dissolved methyl <br /> tertiary-butyl ether(MTBE)plume.The well was developed and sampled during the ground <br /> water monitoring event conducted on 04 January 2007; details of the development and <br /> ' sampling will be included in Quarterly Report-First Quarter 2007. <br /> • On 12, 13, and 15 December 2006, three shallow-screened SVE wells and three <br /> ' deeper-screened SVE wells were installed on-site for use in SVE pilot tests. <br /> • On 26 and 27 December 2006,two 8-hour SVE pilot tests were conducted to provide vapor <br /> extraction data for the proper design of a soil remediation system. The pilot test conducted <br /> ' on 27 December 2006 utilizing the deeper-screened vapor wells was terminated after <br /> approximately 1 hour due to very poor flow rates. <br /> The site and the surrounding area are illustrated on Figure 1;a plan of the site, including soil boring <br /> and well locations, is illustrated on Figure 2. Site background information is summarized in <br /> ' Appendix A. <br /> This report is prepared in accordance with guidelines established by the Central Valley Regional <br /> ' Water Quality Control Board(CVRWQCB)for the investigation ofunderground storage tank(UST) <br /> sites.Field work was performed as detailed in the AGE-preparedAdditional Site Assessment and Soil <br /> Vapor Extraction Pilot Test Work Plan, dated 20 June 2006 and the AGE-prepared Additional Site <br /> ' Assessment and Soil Vapor Extraction Pilot Test Work Plan Addendum,dated 07 August 2006. San <br /> Joaquin County Environmental Health Department(EHD)correspondence and work plan approval <br /> ' letters are included in Appendix B. <br /> ' 2.0. CPT LITHOLOGIC INVESTIGATION <br /> On 22 November 2006, two paired soil borings (CPT-1 and CPT-2) were advanced at the site for <br /> 1 Advanced GmEnvironmental,Inc. <br />