My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008300
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4407
>
2900 - Site Mitigation Program
>
PR0535375
>
ARCHIVED REPORTS_XR0008300
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2020 9:21:50 AM
Creation date
7/7/2020 9:14:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008300
RECORD_ID
PR0535375
PE
2960
FACILITY_ID
FA0020405
FACILITY_NAME
ERNIES GENERAL STORE
STREET_NUMBER
4407
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710059
CURRENT_STATUS
01
SITE_LOCATION
4407 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' 28 December 2004 <br /> i AGE-NC Project No 01-0839 <br />' Page 3 of 4 <br />' The fuel additive 1,2-DCA was detected in the water samples collected from wells MW-3 and MW-4 <br /> at concentrations of 12 µg/1 and 3 3 µg/1, respectively <br />' TAME was detected in the water sample collected from well MW-3 at a concentration of 3 6 99/1 <br /> No other analytes were detected at or above laboratory detection limits in the ground water samples <br />' analyzed The laboratory analytical results are summarized in Table 2 The laboratory report(CTEL <br /> Project No CT214-0409006), quality assurance/quality control (QA/QC) report, and chain of <br /> custody form are included in Appendix C Documents confirming the upload of laboratory electronic <br />' deliverable format (EDF) files and depth to water measurements to GeoTracker are included in <br /> Appendix D <br />' 4.0. SUMMARY AND CONCLUSIONS <br />' The following conclusions were drawn from the results of this investigation <br /> • Ground water elevations at the site ranged from 40 77 feet to 41 01 feet below MSL, <br />' . indicating a decrease in ground water elevation from the previous quarter The inferred <br /> ground water flow direction was northwest at a gradient of approximately 0 004 f1/ft <br /> I0 TPH-g was detected in wells MW-3 and MW-4 <br /> • MTBE and 1,2-DCA were detected for the fifth consecutive quarter <br />' 0 BTEX compounds were not detected in any of the ground water samples analyzed, indicating, <br /> the detections of TPH-g are sole and isolated peaks on the sample chromatography <br /> correlating only to MTBE <br />' 5.0. RECOMMENDATIONS <br /> Based on the findings of this investigation, AGE recommends <br /> • Continuation of the quarterly ground water monitoring program <br /> • Preparation of a work plan to characterize the extent of soil contamination beneath the <br /> existing/former UST location <br /> • Preparation of a work plan to characterize the extent of ground water contamination down <br />' gradient of the existing/former UST location and MW-4 <br /> • <br /> Advanced GeoEnvironmental,Inc <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.