Laserfiche WebLink
ECOLUMBIA ANALYTICAL SERVICES,INC. <br /> Analytical Report <br /> Tient AMERCO heal Estate Company Service Request 1.2003109 <br /> Protect U-Haul/#709-50/002-70950-02 Date Collected. 9/27100 <br /> Sample Matrix Water Date Received: 9129100 <br /> Volatile Organic Compounds <br /> Sample Name MW-6-900-B Units ug/L(ppb) <br /> Lab Code L2003109-006 Basis NA <br /> Test Notes C2A <br /> Prep Analysis Dilution Date Date Result <br /> Analyte Method Method MRL Factor Extracted Analyzed Result Notes <br /> Benzene EPA 5030 8260B 05 200 NA 10/12/00 15000 D2A <br /> Toluene EPA 5030 8260B 0 5 50 NA 10/11/00 760 <br /> Ethylbenzene EPA 5030 8260B 05 50 NA 10/11/00 1900 <br /> Xylenes,Total EPA 5030 8260B 1 50 NA 10/11/00 6700 <br /> Methyl tert-Butyl Ether EPA 5030 8260B 2 50 NA 10/11/00 <100 <br />' rt-Butyl Alcohol EPA 5030 8260B 20 50 NA 10/11/00 <1000 <br /> iisopropyl Ether EPA 5030 8260B 2 50 NA 10/11/00 <100 <br /> Ethyl tert-Butyl Ether EPA 5030 8260B 2 50 NA 10/11/00 <100 <br /> tert-Amyl methyl Ether EPA 5030 8260B 2 50 NA 10/11/00 <100 <br /> 1 <br /> C2A MRL is elevated because of matrix interferences and because the sample required diluting <br /> 132A Sample was analyzed 01 day past the end of the recommended maximum holding time Initial analysis, <br /> performed within the recommended maximum holding time,failed CAS QC criteria The reanalysis <br /> met our QC criteria It is the opinion of CAS that the quality of the sample data has not been <br /> significantly affected <br /> L9 <br />' Approved ByDate 1 L lP <br /> 1S221020597p <br /> 6260Woxy XLT <br /> 03109VOA A82-Setnpk I 6100 <br />