My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1103
>
2300 - Underground Storage Tank Program
>
PR0232587
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/31/2020 8:57:28 AM
Creation date
7/7/2020 2:41:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0232587
PE
2361
FACILITY_ID
FA0004521
FACILITY_NAME
CHEVRON USA #201761*
STREET_NUMBER
1103
Direction
S
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95337
APN
21935038
CURRENT_STATUS
01
SITE_LOCATION
1103 S MAIN ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> E �i 0 4 2020 <br /> F 'BA1RECEIVED 76 <br /> � I IV Environmental Health Department <br /> T Y / \ <br /> ENVIRONMECNTALaU HtjALTH v�U o <br /> pERMIT / SERVICES <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> CHEVRON USA 9201761 (209) 825-0714 January 02, 2020 <br /> Facility Address: CERS ID: <br /> 1103 S MAIN ST, MANTECA, CA 95337 10181653 <br /> Inspection Contact: Title: Phone: <br /> Luisa Verduzco [ Manager (209) 825-0174 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION - Operating Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> 2 Inspection N Photos 9 Samples Luisa Verduzco , Manager <br /> Service Technician Onsite: Exp. Date: Designated Operator: Exp. Date: <br /> Brent Bowen 06/23/2021 <br /> Service Technician Manufacturer's Training : <br /> VR , 04/21 /21 , VMI , 07/19/21 <br /> CCR = Title 23 California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br /> V = Violation R = Repeat violation COS = Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 ; CCR Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees o V o R o COS <br /> 2711 (d) <br /> 102 HSC 25284(a)(3) (A)/(B) No written agreement between tank owner and tank operator to monitor the tank system c V o R e COS <br /> 103 HSC 25292,2, 25299. 30 Failure to submit and maintain complete and current financial responsibility documents o V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current c V o R o COS <br /> 105 CCR 2632(d)(1 ) , Failed to have an approved UST monitoring plan c V o R o COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2) , Failed to have an approved UST response plan ❑ V o R o COS <br /> 2634(e) <br /> 107 CCR 2632(d), 2641 (h), Plot plantshe map not submitted or failed to completely show where monitoring is performed o V o R o COS <br /> 2711 (a) <br /> 108 CCR 2637, 2638(e), Failed to notify the EHD 48 hours prior to conducting testing o V n R o COS <br /> 2643(8) <br /> 109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months o V e R ❑ COS <br /> 110 CCR 2637(e), 2637(!) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test o V e R D COS <br /> 111 CCR 2638, 2641 Q), Failed to test monitoring and leak detection equipment every 12 months o V o R o COS <br /> 2715(f) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance o V o R o COS <br /> 113 CCR 2638(c), 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test o V D R D COS <br /> 114 CCR 2636(f)(3), 2643(c) No 0 . 1 gph annual line integrity test for pres7uhzed piping , or within 30 days after repair o V o R o COS <br /> (3) <br /> 115 CCR 2715(a)( 1 )(8) , "Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days e V o R o COS <br /> 2715(a)(3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification o V o R o COS <br /> 117 CCR 2663, 2712(b)(6) Failure to comply with tank lining, recordkeeping, and inspection requirements o V o R ❑ COS <br /> 118 CCR 2715(a) ( 1 )(A) , Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" D V ❑ R ❑ COS <br /> 2715(a)(2) <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented ❑ V D R o COS <br /> 25299(b)(7) <br /> 120 CCR 2635 (d) Failed to submit UST Certification of Installation/Modification o V e R o COS <br /> 121 CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report o V ❑ R D COS <br /> 122 CCR 2631 , 2640. 11 Failure to submit and/or maintain documentation regarding compatibility for UST system components o V ❑ R ❑ COS <br /> 2665, 2711 <br /> FA0004521 PR0232587 SCO01 0110212020 <br /> EHD 23-01 Rev 9202019 Pagel of 5 Underground Storage Tank Program OIR <br /> 1868 E Hazelton Avenue ( Stockton , California 95205 1 T 209 468 - 3420 F 209 464-0138 1 www sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.