Laserfiche WebLink
1 <br /> RECEIVED FEB 042010 RECEIVE ® <br /> SAN J O A Q U I N Environment 9jtN9epartment <br /> C C u ls%j i' Y <br /> ENVIRONMENTAL HEALTH <br /> PERMIT / SERVICES <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: TDate:CHEVRON USA #201761 ' 1103 S MAIN ST, MANTECA nuary 02, 2020 <br /> UST System Observations <br /> 314 HSC 25290. 1 , 25290.21 Failed to have secondary containment or secondary containment not tight e V e R o COS <br /> 25291 <br /> 315 HSC 25291 (e) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003) o V o R ❑ COS <br /> 316 HSC 25290. 1 (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V DR c COS <br /> 25290.2(c3) <br /> 317 CCR 2636, 2643(c)(1 ), Line leak detector (LLD) not installed ❑ V o R c COS <br /> 2866(f) <br /> 318 CCR 2666(c) , 2643(c) Leak detector failed to detect a 3. 0 gallons per hour leak at 10 pounds per square inch o V o R n COS <br /> (1 ) <br /> 319 CCR 26350 2637. 13 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested o V ❑ R ❑ COS <br /> 2665, 2712 <br /> 320 CCR 2635, 2637. 21 Failure to comply with the installation, inspection, or record keeping of the overfill prevention ❑ V o R o COS <br /> 2665t2712 <br /> 321 CCR 2635(c)(1 ) Overfill prevention was overridden o V o R o COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status o V n R o COS <br /> 323 HSC 25283. 5(9) Unburied below grade UST system failed to meet exemption status o V n R o COS <br /> 324 CCR 2717 . 1 (8) Tampered with red tag o V c R o COS <br /> 325 CCR 2717 . 1 (f), Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST o V o R o COS <br /> 25292. 3(c) <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored ❑ V o R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements ❑ V o R ❑ COS <br /> 329 HSC 25298; CCR 2670, Failed to comply with all permanent closure requirements o V o R ❑ COS <br /> 2672 <br /> 330 CCR 2636(f) , 2666(c), No LLD on the emergency generator that restricts or shuts off the Flow or triggers an alarm o V ❑ R n COS <br /> 2666(() <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e. , failure to remove test boot) . o V o R c COS <br /> 332 CCR 2631 (b&d) , Primary andror secondary containment not constructed in accordance with the established standards u V n R o COS <br /> 2666(b&e) <br /> 333 CCR 2635, 2636(b), Failure to comply with the cathodic protection system requirements o V ❑ R o COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double•walled interstitially monitored pipe during repair ❑ V ❑ R o COS <br /> 335 CCR 26304 2632 , 2643, Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V o R o COS <br /> 2644. 1 <br /> 336 HSC 25292. 3(c)( 1 )(C) Owner/operator allowed dispensing from a UST that has a red tag affixed to the fill pipe o V o R o COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2836 (a)(3) , Suction piping not properly sloped or incorrectly located check valve n V o R n COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring ! maintain records for single-walled conventional suction (pre- 1984) o V ❑ R o COS <br /> 403 CCR 2643(d), 2661 (() Failure to conduct 0. 1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V o R o COS <br /> 404 CCR 2643(e), 2661 (f) 0 . 1ogph line test for single-walled gravity piping not performed bienniaty or post repair (preA984) o V o R ❑ COS <br /> Other Violations <br /> 2010 See below Unlisted General violation o V ❑ R ❑ COS <br /> FAD004521 PR0232587 SC001 01 /02/2020 <br /> EHD 23,01 Rev 9!202019 Page 3 Of 5 Underground Storage Tank Program OIR <br /> 1868 E Hazelton Avenue Stockton , California 95205 I T 209 468-3420 1 F 209 464-0138 1 www s cehd . com <br /> ) <br />