Laserfiche WebLink
Chevron Monitoring Certification Checklist <br /> Store Number: Address: 9484 West Lane Stockton, CA 95210 <br /> Date : 2/ 12/2020 Technician : Jesus Saldivar Company: TANKNOLOGY INC. <br /> Step Instruction T2 : Regular T1 : PREM . T3 : diesel <br /> Product REGULAR PREMIUM Diesel <br /> Tank Type Fiberglass Fiberglass Fiberglass <br /> (DW FRP, DW Steel, SW FRP) <br /> 1 Annular Riser Height ( measured ) <br /> 2 Tank Diameter: (from tank chart <br /> 119 . 00 in. 92 .00 in. 92 .00 in. <br /> for example: 118. 375 ", 11Z ;92 ", etc. ) <br /> 3 For FRP tanks, 1/2 circumference of the tank <br /> 186 . 83 in. 144 .44 in. 144 .44 in. <br /> (0.5 X 3. 14 X tank diam.) OR (q.57 x step 2J <br /> Required annular sensor length : <br /> 4 FRP = Riser + 112 Circumference = step 1 + step 3 186 . 83 in. 144 .44 in. 144 .44 in. <br /> Steel = Riser + diameter = step 1 + step 2 '.. <br /> Mark & label the required sensor length on <br /> 5 sensor cord . Label should be under the cap & Yes Yes Yes <br /> serve to prevent the cord being pulled too short . <br /> Is tank annular sensor in the correct position ? <br /> Yes Yes Yes <br /> 6 FRPTanks: with the marked required length <br /> lining up with the top of the annular riser? Yes Yes Yes <br /> Steel Tanks: sensor touching bottom with slack <br /> above the marked required sensor length ? <br /> Are the DW pipe boots pulled back in tank sumps? <br /> 8 (Y/Al or N/A, note if can 't be verified because Yes Yes Yes <br /> clamshell pointing down) <br /> Are tank sump sensors back in their holders and <br /> 9 in the correct position ? Yes Yes Yes <br /> (YIN or N/A document with photo) <br /> 7 Approximate gallons of product dispensed for <br /> purging, etc . and returned to tank <br /> Has the Veeder Root Battery been replaced & dated prior to failsafe ? Replaced Today <br /> (if battery backup failed, label and leave failed battery on top of console, note in comments and advise your OM) <br /> Has Veeder Root Programming before & after testing been printed & verified ? <br /> Yes <br /> (especially tank manifolding setup - see Note 2) <br /> Has Veeder Root Programming before & after been attached to the Work Order? Yes <br /> Have all sensor model numbers been verified against the Veeder Root cord label ? Yes <br /> Make a note if sensor label missing or illegible, & approx. cord length for -208/-209 with missing labels <br /> Additional Comments : <br /> ALLTANKS ON SITE HAVE 301 BRINE SENSORS IN ANNULARS .. . <br /> I <br /> Note 1: Certain Veeder Root Software versions will automatically revert to the default tank manifold settings anytime the programming is changed, such as when sensors are <br /> temporarily X'ed out, etc. <br />