My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0007240
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
2701
>
3500 - Local Oversight Program
>
PR0540315
>
ARCHIVED REPORTS_XR0007240
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/7/2020 3:03:06 PM
Creation date
7/7/2020 2:46:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0007240
RECORD_ID
PR0540315
PE
3526
FACILITY_ID
FA0023046
FACILITY_NAME
U-HAUL FACILITY NO 710050
STREET_NUMBER
2701
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95215
APN
11708014
CURRENT_STATUS
01
SITE_LOCATION
2701 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
142
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 Ii�i�1#707 �(3 Bh1 4 i In]IouIII it <br /> Rt iilerh II 1 t Isibil11 E ,t Kcpot 1 E c In n i i ti 1 , ' (J) <br /> ' 800C mechanical flow meter was installed in-line (at the ground surface) on the pump discharge hose to <br /> measure the total purge gallons extracted from the well <br /> I ' <br /> The MW-6C pump test lasted approximately 20 hours A total of approximately 2,493 gallons were <br /> ' purged from MW-6C during the 20 hour period which equates to a pumping rate of approximately 2 <br /> gallons per minute or 125 gallons per hour At periodic intervals during the pump test, Blaes <br /> ' Environmental monitored the water levels in extraction well MW-6C and surrounding monitor wells <br /> MW-6B, MW-9B, MW-2C, and MW-2B using a Heron groundwater level meter Static groundwater <br /> ' levels recorded during the MW-6C pump test are provided in Table 9 After approximately 20 hours of <br /> pumping, the maximum draw down (as measured with the Heron water level meter) in the extraction <br /> ' well (MW-6C) was measured at 1 18 feet (Figure 9) The maximum elevation change as measured by <br /> the Solinzst level loggers equated to approximately 125 feet in extraction well MW-6C and <br /> ' approximately 0 23 feet in monitor well MW-6B (located approximately nine feet from MW-6C) <br /> ' At the conclusion of the pump test, the data loggers were removed from each well and subsequently <br /> connected to a laptop computer for data transfer The transferred data was analyzed using AQTE50LV <br /> ' software according to the Theis (1935)method for pump tests in unconfined aquifers Results of the data <br /> analysis indicated a transmissivity of 0 01615 ft2/minute and a storatyvity of 1 x 10-10 This equates to a <br /> ' hydraulic conductivity value of approximately 2 6 x 10-4 cm/s This hydraulic conductivity value <br /> corresponds with a soil type of silty sand, which relates (in general) to the soil types described in boring <br /> ' logs from drilling activities conducted at the site A copy of the data analysis derived from the <br /> AQTESOLVE software program is included in Appendix H <br /> ' 4 3 2 MW-3C Pump Test <br /> On November 21, 2002, Blaes Environmental began the MW-3C pump test Prior to commencing <br /> ' groundwater pumping, a Solmst data logger was installed in the extraction well in order to monitor static <br /> groundwater level changes Additionally,a second data logger was placed in monitor well MW-4C The <br /> ' Grundfos pump was installed at approximately 65 feet below the top of the MW-3C well casing The <br /> Fill-Rite Series 800C mechanical flow meter was again installed on the pump discharge hose to measure <br /> ' the total purge gallons extracted from the well <br /> ' 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.