Laserfiche WebLink
' r 2852 Alton Ave Irvine CA 92606 (949)261 1022 FAX(949)261 1228 <br /> Del Mar Analytical 1014E Cooley 05 A ColtonDiego CA 92324 (9013)370 8596 FAX(909)370 1046 <br /> 9484 Chesapeake Dr Suite 805 San Diego CA 92123 (858♦505 8596 FAX(856)505 9689 <br /> 9830 South 51 at S1 Suite B 120 Phoenix AZ 85044 (480)785-0043 FAX(480)785 0651 <br /> 2520 E Sunset Rd #3 Las Vegas NV 89120 (702)798 3620 FAX(702)798 3621 <br /> / <br /> _ s Envtronmental Project ID 002-70950 Uhaul -Stockton <br /> ' 1433 North Third Avenue 2701 N Wilson Way Sampled 09124/02-09/26102 <br /> Phoenix, AZ 85003 Report Number ILI1342 Received 09/27/02 j <br /> Attention Brett McDaniel <br /> DATA QUALIFIERS AND DEFINITIONS <br /> '1 CR The carbon range of the fuel found in the sample=C8-C 16 <br /> JJCRa The carbon range of the fuel found in the sample=C8-C26 <br /> CRb The carbon range of the fuel found in the sample=C8-C28 <br /> I3 CRe The carbon range of the fuel Found in the sample=C8-C38 <br /> 4 M-HA Due to high levels of analyte to the sample, the MS/MSD calculation does not provide useful spike recovery <br /> information See Blank Spike(LCS) <br /> M-NR1 There was no MS/MSD analyzed with this batch due to insufficient sample volume See Blank SpikelBlank Spike <br /> Duplicate <br /> M2 The MS and/or MSD were below the acceptance limits due to sample matrix interference See Blank Spike (LCS) <br /> M3 Results exceeded the linear range in the MS/MSD and therefore are not available for reporting The batch was <br /> accepted based on acceptable recovery in the Blank Spike(LCS) <br /> R The RPD exceeded the method control limit due to sample matrix effects The individual analyte QA/QC recoveries, <br /> however, were within acceptance limits <br /> Z Due to sample matrix effects, the surrogate recovery was below the acceptance limits <br /> Z5 Due to sample matrix effects, the surrogate recovery was outside acceptance limits Secondary surrogate recovery <br /> 11A— was within the acceptance limits <br /> Due to sample matrix effects, the surrogate recovery was outside the acceptance lit-nits <br /> ND Analyte NOT DETECTED at or above the reporting limit or MDL, it MDL is specified <br /> 1 }RPD Relative Percent Difference <br /> 1 ADDITIONAL COMMENTS <br /> For 8260 analyses <br /> Due to the high water solubility of alcohols and ketones, the calibration criteria for these compounds is<30% RSD <br /> The average %RSD of all compounds in the calibration is 15%, in accordance with EPA methods <br /> For Volatile Fuel Hydrocarbons(C6-C12) <br /> Volatile Fuel Hydrocarbons(C6-C12)are quantitated against a gasoline standard <br /> For Extractable Fuel Hydrocarbons(EFH,DRO,ORO) <br /> Unless otherwise noted, Extractable Fuel Hydrocarbons (EFH, DRO, ORO) are quantitated against a Diesel Fuel Standard <br /> I <br /> Uel Mar Analytical,Irvine <br /> Jim Hatfield <br /> olect Manager <br /> !! The results pertain only to the seonples tested in the laboratory This report shall not be reproduced <br /> except ui full mthout xritten pernrissron froin Det Mar Anatytical ILI1342 <Page 38 of 39> <br />