My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_COMPLIANCE INFO 2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
88 (STATE ROUTE 88)
>
12755
>
3600 - Recreational Health Program
>
PR0360311
>
COMPLIANCE INFO_COMPLIANCE INFO 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 9:21:39 AM
Creation date
7/8/2020 10:39:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
COMPLIANCE INFO 2020
RECORD_ID
PR0360311
PE
3699
FACILITY_ID
FA0000342
FACILITY_NAME
POINT QUEST EDUCATION
STREET_NUMBER
12755
Direction
N
STREET_NAME
STATE ROUTE 88
City
LODI
Zip
95240
APN
06314007
CURRENT_STATUS
01
SITE_LOCATION
12755 N HWY 88
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA NUJ OAHU I N Environmental Health Department <br /> L■ COUNT Y-- <br /> �c/ `p' GreornesS grows hey,. Time In: 11.45 am <br /> Time Out: 1:25 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: POINT QUEST EDUCATION Date: 07/07/2020 <br /> Address: 12755 N HWY 88 , LODI 95240 <br /> Owner/Operator: VICTOR TREATMENT CENTER Telephone: <br /> Program Element: 3699-POOL/SPA-OUT OF SERVICE <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:The following signs require corrections. Provided within one week: <br /> • Keep closed signed is missing.A sign shall be posted on the exterior side of gates and doors leading into the pool <br /> enclosure area stating, "KEEP GATE CLOSED"or"KEEP DOOR CLOSED". <br /> • Diarrhea Sign:The pool operator shall post at the entrance area of a public pool, a sign in letters at least 1 inch (25 mm) <br /> high,that clearly states that persons with diarrhea and persons who have had diarrhea within the prior 14 days shall not <br /> enter the pool water. <br /> • The following signs are faded: Emergency sign showing emergency telephone number 911, number of the nearest <br /> emergency service and the name and street address of the pool facility. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br /> #7 Pool Deck <br /> OBSERVATIONS:There are gaps between pool coping and deck/concrete floor around the pool. Seal these gaps within <br /> one month. <br /> CALCODE DESCRIPTION:An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br /> top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br /> diving board,ADA device, or slide. (CBC 31148)Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The handrails at West and South side are loose. Secure or tighten this handrail within one week. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> FA0000342 PR0360311 SCO01 07/07/2020 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.