My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WETMORE
>
322
>
1900 - Hazardous Materials Program
>
PR0519536
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2020 4:15:16 PM
Creation date
7/8/2020 11:07:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1900 - Hazardous Materials Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0519536
PE
1921
FACILITY_ID
FA0009309
FACILITY_NAME
CONCO-WEST INC
STREET_NUMBER
322
Direction
E
STREET_NAME
WETMORE
STREET_TYPE
ST
City
MANTECA
Zip
95337-5741
APN
22104032
CURRENT_STATUS
01
SITE_LOCATION
322 E WETMORE ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_____________________________________________________________________ <br /> <br /> Revision Number: 3 <br /> Revision Date: June 05, 2019 3 of 7 Delo 400 SDE SAE 15W-40 <br /> SDS : 42671 <br /> <br />General Handling Information: Avoid contaminating soil or releasing this material into sewage and drainage <br />systems and bodies of water. <br />Precautionary Measures: Keep out of the reach of children. <br />Static Hazard: Electrostatic charge may accumulate and create a hazardous condition when handling this material. <br />To minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient. <br />Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a <br />flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch <br />loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures. <br />Container Warnings: Container is not designed to contain pressure. Do not use pressure to empty container or it <br />may rupture with explosive force. Empty containers retain product residue (solid, liquid, and/or vapor) and can be <br />dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks, <br />static electricity, or other sources of ignition. They may explode and cause injury or death. Empty containers <br />should be completely drained, properly closed, and promptly returned to a drum reconditioner or disposed of <br />properly. <br /> <br /> <br /> SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION <br />GENERAL CONSIDERATIONS: <br />Consider the potential hazards of this material (see Section 2), applicable exposure limits, job activities, and other <br />substances in the work place when designing engineering controls and selecting personal protective equipment. If <br />engineering controls or work practices are not adequate to prevent exposure to harmful levels of this material, the <br />personal protective equipment listed below is recommended. The user should read and understand all instructions <br />and limitations supplied with the equipment since protection is usually provided for a limited time or under certain <br />circumstances. <br /> <br />ENGINEERING CONTROLS: <br />Use in a well-ventilated area. <br /> <br />PERSONAL PROTECTIVE EQUIPMENT <br />Eye/Face Protection: No special eye protection is normally required. Where splashing is possible, wear safety <br />glasses with side shields as a good safety practice. <br />Skin Protection: No special protective clothing is normally required. Where splashing is possible, select <br />protective clothing depending on operations conducted, physical requirements and other substances in the <br />workplace. Suggested materials for protective gloves include: 4H (PE/EVAL), Nitrile Rubber, Silver Shield, <br />Viton. <br />Respiratory Protection: No respiratory protection is normally required. <br />If user operations generate an oil mist, determine if airborne concentrations are below the occupational exposure <br />limit for mineral oil mist. If not, wear an approved respirator that provides adequate protection from the measured <br />concentrations of this material. For air-purifying respirators use a particulate cartridge. <br />Use a positive pressure air-supplying respirator in circumstances where air-purifying respirators may not provide <br />adequate protection. <br /> <br />Occupational Exposure Limits: <br />Component Agency Form TWA STEL Ceiling Notation <br />Highly refined mineral oil <br />(C15 - C50) <br />ACGIH --5 mg/m3 10 mg/m3 ---- <br />Highly refined mineral oil <br />(C15 - C50) <br />OSHA Z-1 --5 mg/m3 ------ <br />Consult local authorities for appropriate values. <br /> <br /> SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES <br /> <br />Attention: the data below are typical values and do not constitute a specification.
The URL can be used to link to this page
Your browser does not support the video tag.