Laserfiche WebLink
Oct 1519 12 : 22p Zoom Car Wash 209-957-3428 p . 3 <br /> i <br /> i <br /> The following is an itemized list of hazardous waste violations that have not been <br /> addressed for QUAIL LAKES CAR WASH as of October07, 2019, <br /> Open violations from June 04, 2019 inspection <br /> This violation was corrected ❑ This violation will be corrected by (date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: t' <br /> Py! {•-,yam it <br /> 6 t o � J -!- C k^ , , ti • 1 .' i C> v .' t^ / s rze, <br /> ft <br /> t <br /> Vlolation #501 - Failed to completely label stationary hazardous waste tanks. <br /> The 1000 gallon used oil tank and the 300 gallon used antifreeze tank were missing the accumulation start dates on <br /> the hazardous waste label. <br /> All hazardous waste tanks shall be marked with the words "Hazardous Waste ' and the accumulation start date, <br /> Immediately ensure that all hazardous waste tanks are marked with the required information . <br /> This violation was corrected CI This violation will be corrected by (date): <br /> ❑ Supporting documents Included <br /> Describe actions taken or will betaken to correct violation: Ct ; i. GI ,^: •, ;= cr �.r <br /> Pat ' �-` 4±. \ ' � Y� cl '1^ S ::� •"•1.y^, (:.� SK:: r," 4r .., '0 ^s? r- I `'�-a 1 t"E r'. �` ?'�-s � f. s I e''� <br /> Violation #502 - Failed to comply with new hazardous waste tank system assessment requirements. <br /> Facility does not bave a tank assessment for the 1000 gallon used oil tank and the 300 gallon used antifreeze tank. <br /> The owner or operator of a hazardous waste tank shall obtain a written assessment reviewed and certified by an <br /> independent, qualified , professional engineer, registered: in California attesting that the system has sufficient <br /> structural integrity , is acceptable for the transferring , storing , and treating of hazardous waste, and that the tanks <br /> and containment system are suitably designed , Immediately have an assessment prepared for the 1000 gallon <br /> used oil tank and the 300 gallon used antifreeze tank. Submit a schedule showing when this will be accomplished <br /> to the EHD and submit a hazardous waste tank assessment once this has been completed . <br /> ❑ This violation was corrected *This violation will be corrected by (date) : `- ' <br /> CI Supporting documents included <br /> Describe actions taken or will be taken to correct violation : w, -t t'� f'- ' ' ` a } ., 4 r ; <br /> C43H "5 +tj:^,:.:� - "> . .i 'i'"':.i +" , , <br /> Violation #601 - Stored hazardous waste on site longer than 90 days without a permit or authorization . <br /> The 1000 gallon used oil tank and the 300 gallon used antifreeze tank were missing the accumulation start dates on.: <br /> the hazardous waste label. <br /> Facilities who generate more than 1000 kg of hazardous waste per month may store waste on site up to 90 days. <br /> Since it cannot be determined how long the hazardous waste has been on site , immediately contact a licensed <br /> hazardous waste hauler to dispose of this waste under manifest or a disposal record showing that the waste had <br /> been generated within 90 days, Submit a copy of the manifest to the EHD within 30 days. <br /> Page2of3 <br />