Laserfiche WebLink
Analysis • • <br /> Lancaster Laboratories Page 2 of 2 <br /> Where quality is a science <br /> Quality Control Summary <br /> Client Name Chevron Products Company Group Number 803061 <br /> Reported 04/16/02 at 05 42 PM <br /> Surrogate Quality Control <br /> Analysis Name TPH-GRO - Waters <br /> Batch number 02099A56A <br /> Trzfluorotoluene-F Trafluorotoluene-P <br /> 3801238 89 100 <br /> 3801239 88 100 <br /> 3801240 91 97 <br /> 3801241 89 100 <br /> Blank 90 101 <br /> LCS 101 99 <br /> LCSD 101 99 <br /> MS 103 100 <br /> Limits 67-135 71-130 <br /> Analysis Name Methanol and Ethanol <br /> Batch number 021000018A <br /> Acetone <br /> 3801239 97 <br /> 3801240 98 <br /> 3801241 95 <br /> Blank 94 <br /> LCS 99 <br /> S 96 <br /> SD 96 <br /> Limits 72-128 <br /> Analysis Name BTEX + Oxygenates by 82608 <br /> Batch number P021003AB <br /> Dibromofluoromethane 1,2-Dichloroethane-d4 Toluene-d8 4-Bromofluorobenzene <br /> 3801239 93 93 94 88 <br /> 3801240 94 92 93 88 <br /> 3801241 94 92 93 87 <br /> Blank 93 92 94 89 <br /> LCS 92 93 96 92 <br /> MS 93 93 95 90 <br /> MSD 93 92 95 90 <br /> Limits 86-118 80-120 88-110 86-115 <br /> *-Outside of specification <br /> } The result for one or both determinations was less than five times the LOQ <br /> The background result was more than four times the spike added <br /> Lancaster Laboratories Inc <br /> M E M B E R 2425 New Holland Pike <br /> PO Box 12425 <br /> KFLancaster PA 17605 2425 <br /> 717 656 2306 Fax 717 656 2681 2216 Rev 9111100 <br />