Laserfiche WebLink
aUlty <br /> pP.... .. . . c <br /> °2 SAN J O A Q U I N Environmental Health Department <br /> � COUNTY — <br /> Wayne Fox , REHS , Interim Director <br /> %I <br /> c� 44FORM Greatness grows here . PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> July 13 , 2020 <br /> MEGAN MITCHEL <br /> ELITE IV CONTRACTORS <br /> 2535 WIGWAM DR <br /> STOCKTON , CA 95205 <br /> Re : Estes Express Lines SR0082308 <br /> 7611 S Airport way <br /> Stockton , CA 95206 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a 1 hour plan check service request to replace interstitial manhole on the underground <br /> storage tank ( UST) system at the above noted address . The plan check service request has been <br /> approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust( slgov . orq for the following repairs and testing ( a 48 - hour <br /> notice is required ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of plan check service request approval . <br /> a . Since concrete will be broken near the UST and product piping , a secondary containment <br /> test must be performed on the UST and product piping once concrete is poured in <br /> accordance with the manufacturer' s guidelines , and test results submitted to the EHD within <br /> 30 days of testing . <br /> Please be aware that the facility cannot receive fuel in the diesel tank prior to completion <br /> of passing secondary containment testing and submission of notification of passing test <br /> results to the EHD . <br /> 4 . Secondary containment testing for the UST and product piping is required six months after <br /> installation . Provide 48 hours notification to the EHD when this test is scheduled . <br /> 5 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468 -3420 1 F 209 464 - 0138 1 www. sjcehd . com <br />