My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0082189 SSNL
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
12448
>
2600 - Land Use Program
>
SR0082189 SSNL
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/9/2020 10:57:44 PM
Creation date
7/9/2020 2:11:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
FileName_PostFix
SSNL
RECORD_ID
SR0082189
PE
2602
STREET_NUMBER
12448
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06324025
ENTERED_DATE
6/12/2020 12:00:00 AM
SITE_LOCATION
12448 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
TSok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Per San Joaquin County Environmental Health Department's definition, a shallow <br /> percolation test hole has a depth between 36 and 42 inches; a satisfactory percolation <br /> rate for a shallow test is greater than or equal to 1 minute per inch (min/in) but less than <br /> or equal to 60 min/in drop. A deep percolation test hole has a depth between 36 inches <br /> and 25 feet; a satisfactory percolation rate for a deep test is greater than or equal to 1 <br /> minute per inch (min/in) but less than or equal to 30 min/in drop. For the Site to utilize a <br /> standard septic system, one percolation test (shallow or deep) must demonstrate a <br /> satisfactory percolation rate within 100 feet of the proposed septic system disposal field. <br /> Details and results of the percolation test are summarized in the following table. <br /> Table 2. Percolation Test Summary <br /> Test No., Percolation Test Percolation Rate Test Duration Comments <br /> Date Tested Depth (ft.) (minutes/inch) (see notes) <br /> P1, No movement, <br /> 6/2/2020 3.36 --- 4 hr. <br /> Shallow Test failed <br /> P1, Satisfactory perc. <br /> 6/2/2020 25.0 12.5 4 hr. rate <br /> Deep Test <br /> Note: A satisfactory percolation rate for a "shallow" test is greater than 1 but less than or equal to 60 minutes per <br /> inch. A satisfactory percolation rate for a "deep" test is greater than 1 but less than or equal to 30 minutes <br /> per inch. <br /> Only one percolation test (shallow or deep) must demonstrate a satisfactory percolation rate for the area to <br /> be considered acceptable for a standard septic system. <br /> 1 Per San Joaquin County Environmental Health Department, a rate between 5.0 and 30.0 min/in requires an <br /> eight-foot separation between the bottom of dispersal system and ground water, or mitigation by system <br /> design or enhancement. <br /> Discussion of Percolation Test Results <br /> The soils within the proposed sewage disposal area of the Site have demonstrated a <br /> satisfactory percolation rate for the use of standard septic systems in accordance with <br /> the requirements of the San Joaquin County Environmental Health Department. This <br /> percolation test is considered representative of soils within a 100-foot radius of the test <br /> location. <br /> Because of the percolation rate between 5.0 and 30.0 min/in encountered in the test <br /> hole, the San Joaquin County Environmental Health Department will require an eight- <br /> foot separation from the bottom of the dispersal system to ground water. Ground water <br /> is anticipated to be encountered approximately 120 to 127 feet below ground surface at <br /> the Site; consequently, no modifications to standard septic systems should be required. <br /> LOGE 20-20 Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.