Laserfiche WebLink
SANOAQU I N Environmental Health Department <br /> COUNT -( IY <br /> Crea rne3S grows here, Time In: 3.00 pro <br /> Time Out: 4:00 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: COUNTRY MANOR MOBILE ESTATES Date: 08/24/2018 <br /> Address: 17251 N TRETHEWAY RD, LOCKEFORD 95237 <br /> Owner/Operator: LEPELLEY FAMILY TRUST Telephone: (209)452-0000 <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The pool light has been disconected from the circuit. The manager showed me the disconnected wires. <br /> No swimming after dark is permitted unless light is reconnected. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31158) <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The main hand rail in the shallow end is loose,the hand rails should be secured to the deck. Secure the <br /> handrail by the next routine inspection. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool.Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step.Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:There is a crack in the pool shell near the shallow end. Fill the crack or replace the tile before the next <br /> routine inspection. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 31088) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 60 gpm Chlorine: 6.1 ppm Temp: 83.00 ° F <br /> Cyanuric acid: <30 ppm pH: 7.5 Combined chlorine: 0.4 ppm <br /> NOTES <br /> Influent Pressure: 8 psi <br /> FA0000063 PR0360334 SCO01 08/24/2018 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />