Laserfiche WebLink
A J OA U I Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> JD Service Station, Inc. 9015 WALNUT GROVE RD, THORNTON May 20, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 320 CCR 2635, 2637.2, 2665, 2712 Failure to comply with the installation, inspection, or record keeping of the overfill <br /> prevention. <br /> OBSERVATION: The overfill prevention test results dated 9/26/18 state the probes are set to activate at 107 inches <br /> from the bottom of the tanks. <br /> Based on the tank charts, this places the overfill at 94.8% of the tank volume. Audible/visual overfill prevention <br /> methods shall be set to alarm at or below 90% of the tank volume. <br /> REGULATION GUIDANCE: All UST systems must be equipped with an approved, functional overfill prevention <br /> device at all times during delivery operations. <br /> CORRECTIVE ACTION: Immediately discontinue deposition of petroleum into this tank until the component is <br /> repaired or replaced by a properly licensed, trained, and certified contractor under permit and inspection of the EHD. <br /> If the failed component can't be replaced immediately, there is a possibility that the 87, 91 and diesel UST system <br /> may be red tagged to prevent fuel inputs. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 06/19/2020 . <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209) 468-3420. <br /> Documents provided during inspection: Return to compliance certification form and corrective action statement <br /> form. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: May 20, 2020 Inspector: Inspector Phone: <br /> Printed Name and Title: PAUL NSO, EHS Trainee (209)468-3432 <br /> Nasim Tarin, Owner <br /> FA0014762 PR0521738 SCO01 05/20/2020 <br /> EHD 23-01 Rev.9/20/2019 Page 6 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />